2021-04-23 20:52:14 -0500 | received badge | ● Popular Question (source) |
2020-04-20 20:46:32 -0500 | commented question | ExpandObjects Program Error Yes I do have it. |
2020-04-20 09:04:18 -0500 | commented question | ExpandObjects Program Error Just running it from EP-Launch |
2020-04-20 05:08:40 -0500 | asked a question | ExpandObjects Program Error ExpandObjects Program Error Hi, I am trying to run a model with HVAC Template in EnergyPlus 9.1 but the following error |
2017-10-03 20:25:01 -0500 | commented question | Load Distribution with "Sequential Load" in E+ Hi @julien marrec, I have added the code for those two classes. The graphs are line graphs with red crosses marking th |
2017-10-03 20:23:08 -0500 | edited question | Load Distribution with "Sequential Load" in E+ Load Distribution with "Sequential Load" in E+ I have found this problem in EnergyPlus for quite a while already perhaps |
2017-10-03 06:09:15 -0500 | asked a question | Load Distribution with "Sequential Load" in E+ Load Distribution with "Sequential Load" in E+ I have found this problem in EnergyPlus for quite a while already perhaps |
2017-06-16 05:17:40 -0500 | commented question | Water Heater Heat Pump with Outdoor Air Temperature falls below Min. Temp @Aaron Boranian I have tried to simplify the plant from 4 heat pumps into 1. Its behaviour was still abnormal when the t |
2017-06-16 05:16:30 -0500 | received badge | ● Editor (source) |
2017-06-16 05:16:30 -0500 | edited question | Water Heater Heat Pump with Outdoor Air Temperature falls below Min. Temp Water Heater Heat Pump with Outdoor Air Temperature falls below Min. Temp I am simulating a hot water plant with WaterHe |
2017-06-14 10:38:24 -0500 | received badge | ● Teacher (source) |
2017-06-14 05:17:51 -0500 | answered a question | All electric HVAC system? You could consider using PTHP/PTAC (using electric for heating coil) for your small single zone. It is a single zone equ |
2017-06-13 21:35:26 -0500 | commented question | Water Heater Heat Pump with Outdoor Air Temperature falls below Min. Temp Thanks for the tips @Aaron Boranian . I have inserted the code in my question. I discover a little more about what is |
2017-06-13 21:34:01 -0500 | edited question | Water Heater Heat Pump with Outdoor Air Temperature falls below Min. Temp Water Heater Heat Pump with Outdoor Air Temperature falls below Min. Temp I am simulating a hot water plant with WaterHe |
2017-06-13 03:29:59 -0500 | asked a question | Water Heater Heat Pump with Outdoor Air Temperature falls below Min. Temp Water Heater Heat Pump with Outdoor Air Temperature falls below Min. Temp I am simulating a hot water plant with WaterHe |
2017-06-11 21:16:41 -0500 | commented answer | Integrated Heat Pump Yes my system is the same as @Chris Jones has described. My ASHP uses outdoor air as a source and provides hot/chilled w |
2017-06-08 21:38:33 -0500 | commented answer | Integrated Heat Pump Thanks! It was such a detailed answer. So basically EnegryPlus cannot model ASHP as a plant equipment but only as a sys |
2017-06-08 20:48:03 -0500 | commented answer | Integrated Heat Pump Thanks! It was such a detailed answer. So basically EnegryPlus cannot model ASHP as a plant equipment but only as a sys |
2017-06-08 20:45:08 -0500 | received badge | ● Supporter (source) |
2017-06-08 20:45:06 -0500 | marked best answer | Integrated Heat Pump I have a system that comprises 4 air-sourced heat pumps for both space heating and cooling. I saw the new integrated heat pump coil system can model a single air-sourced heat pump so it cannot provide both heating and cooling simultaneously. Is it possible to connect the integrated heat pumps in parallel so that the plant can supply both hot water and chilled water? Or must I stay with 4 air-cooled chiller + 4 Coil:WaterHeating:AirToWaterHeatPump in order to achieve that? |
2017-06-08 06:32:21 -0500 | asked a question | Integrated Heat Pump Integrated Heat Pump I have a system that comprises 4 air-sourced heat pumps for both space heating and cooling. I saw t |
2017-02-23 20:17:21 -0500 | commented answer | Two chilled water loop with different temperature Thanks. As my heat pumps are connected to the same condenser loop and hot water loop but to different chilled water loops, is it still possible to set up 2 central heat pump system and connect them as designed? |
2017-02-20 01:46:25 -0500 | asked a question | Two chilled water loop with different temperature Hi, I have a building that has 2 chilled water loop with different loop temperature. Each is cooled by a water-to-water heat pump and providing chilled water to different equipment. Is it possible to have 2 separate chilled water loop with water-to-water heat pumps rejecting heat to the same hot water loop in EnergyPlus? |
2016-09-19 01:13:00 -0500 | received badge | ● Scholar (source) |
2016-09-19 01:12:29 -0500 | commented answer | Exhaust Heat Recovery Thanks for your advise! I think I will explore the option of using EMS to modify the district heating loop input depending on the energy recovered from the exhaust air. |
2016-09-13 06:40:57 -0500 | received badge | ● Student (source) |
2016-09-13 00:03:10 -0500 | asked a question | Exhaust Heat Recovery Hi all, I am trying to model a system which has heat recovery coil designed at all exhaust air stream in E+. I can only see unitary system has the capability to add heat recovery coils at exhaust but my systems are mostly VAV distribution system. Any suggestion on how to model it? |