2023-01-09 11:33:27 -0500 | commented question | Unitary system (Water- Air) CC control issues @MJWitte - Files submitted to energy plus support- https://energyplushelp.freshdesk.com/support/tickets/16322 |
2023-01-09 10:08:30 -0500 | commented question | Unitary system (Water- Air) CC control issues @MJWitte- Files submitted to energy plus support- https://energyplushelp.freshdesk.com/support/tickets/16322 |
2023-01-09 10:08:11 -0500 | commented question | Unitary system (Water- Air) CC control issues @MJWitte- Files submitted to energy plus support deck- https://energyplushelp.freshdesk.com/support/tickets/16322 |
2023-01-04 12:56:51 -0500 | asked a question | Unitary system (Water- Air) CC control issues Unitary system (Water- Air) CC control issues Hello fellow modelers! Happy new year! Background- In an attempt to mod |
2021-02-02 11:17:01 -0500 | marked best answer | Space type configuration in PNNL prototypes Fellow energy modelers, Where can I find space type blending that was used in the PNNL prototypes? Nithya |
2020-11-06 10:57:39 -0500 | asked a question | Space type configuration in PNNL prototypes Space type configuration in PNNL prototypes Fellow energy modelers, Where can I find space type blending that was used i |
2020-09-08 11:46:21 -0500 | commented answer | Open DOE 90.1-2016 prototypes in OpenStudio? Any update on this effort? |
2020-09-03 12:31:21 -0500 | commented answer | Written report accompanying the DOE prototype models @mdahlhausen, has there been a measure update for creating the prototypes using the newer version of Open Studio? |
2020-07-13 22:00:04 -0500 | commented question | Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling? I have similar issue. Were you able to resolve this? |
2020-07-12 17:41:00 -0500 | answered a question | Where can I find the error details for OpenStudio? Open studio generates a folder with the same name as your osm file. In that folder, open sub folder called 'Run'. In the |
2020-07-08 06:23:20 -0500 | commented answer | Using chiller to temper WSHP loop Khaddad, I need to use a chiller(~air to water heat pump) for this scenario. I am using manufacturer data to create perf |
2020-07-06 16:01:05 -0500 | commented answer | Using chiller to temper WSHP loop Khaddad, I need to use a chiller(~air to water heat pump) for this scenario. This is a research based project and I am u |
2020-07-05 07:07:36 -0500 | asked a question | Using chiller to temper WSHP loop Using chiller to temper WSHP loop Can anyone share how to use chiller that supplies 44F to temper WSHP loop to operate a |
2018-04-30 12:06:11 -0500 | marked best answer | GLHE with Energy plus file Is it possible to run the GLHEPro setup with energy plus file? |
2018-04-25 10:43:03 -0500 | commented answer | GLHE with Energy plus file What is the information that GLHE pro needs? I do not have a purchased version yet as I am still figuring out if it is u |
2018-04-24 13:21:13 -0500 | commented answer | GLHE with Energy plus file Is it possible to extract the same type of data from energy plus file that you would need to run the GLHE pro? |
2018-04-20 14:06:04 -0500 | asked a question | GLHE with Energy plus file GLHE with Energy plus file Is it possible to run the GLHEPro setup with energy plus file? |
2018-04-19 20:02:23 -0500 | commented question | What is wrong with this vertical ground source loop configuration! Main plant is set to 55F with Plant sizing component set to 55F -delta 10F. For each component: -The GSHP is set to mai |
2018-04-19 15:12:36 -0500 | received badge | ● Commentator |
2018-04-19 15:12:36 -0500 | commented question | What is wrong with this vertical ground source loop configuration! Also, Open Studio team---- by default Open Studio puts in a 'Site:GroundTemperature:BuildingSurface' as the reference Gr |
2018-04-19 11:36:05 -0500 | asked a question | What is wrong with this vertical ground source loop configuration! What is wrong with this vertical ground source loop configuration! I have a plant setup with vertical ground source and |
2018-04-06 09:20:51 -0500 | commented answer | replacing osm geometry changes from one file to another Has this measure been updated to keep the zone assignment? |
2018-04-06 09:16:34 -0500 | commented answer | Any guideline specifying the heat distribution for ElectricEquipment In a case where there is Kitchen exhaust, if you modeled the exhaust fan as zone equipment, would you assign fraction lo |
2018-03-27 21:06:28 -0500 | asked a question | Open studio zone report Open studio zone report I have used the zone report for my model and wondering if I am understanding the result accurate |
2017-07-06 09:46:39 -0500 | commented answer | open studio pat v2 Julien, Thank you for the help with this. I do have a couple of comments on your answers 2- I did this already but i st |
2017-07-05 15:45:22 -0500 | answered a question | Can you point me to a good source to look up lighting and HVAC schedules (hourly profile) for data centers and 24-hour restaurants? You can find these here- https://comnet.org/appendix-c-schedules a column to the right of the schedules shows which buil |
2017-07-05 15:14:12 -0500 | asked a question | open studio pat v2 open studio pat v2 I am running into a couple of issues with the new PAT and looking for a solution. Currently using a v |
2017-07-05 09:39:43 -0500 | marked best answer | Adding field to Fan coil unit inputs I am using v1.14 and trying to model a Fan coil unit with fan operating on a schedule- unfortunately, the osm file does done have supply air fan operating mode field that makes it relevant to operate the unit at that schedule and cycle it per demand at other hours. It is only operating as either run as constant(24X7) or cycling it on demand(OA cycles as well!!!!). How can I get this to work? The following text is from energy plus i had edited to make it work. I prefer to stay in the open studio platform inorder to run parametrics using PAT. Please help!!!! |
2017-07-03 13:47:44 -0500 | asked a question | Adding field to Fan coil unit inputs Adding field to Fan coil unit inputs I am using v1.14 and trying to model a Fan coil unit with fan operating on a schedu |
2017-05-19 11:40:50 -0500 | marked best answer | Boiler nominal capacity Has anyone come across this issue where the total load from coil:heating:water does not add up to nominal capacity of both the Boilers? infact the load is exactly twice! |
2017-05-18 12:04:34 -0500 | asked a question | Boiler nominal capacity Boiler nominal capacity Has anyone come across this issue where the total load from coil:heating:water does not add up t |
2017-03-21 13:00:26 -0500 | received badge | ● Scholar (source) |
2017-03-21 12:59:12 -0500 | commented answer | replacing osm geometry changes from one file to another @David, thank you! I tried the merge spaces by deleting the spaces and merging those spaces. The only setback is the the space to zone linkage is gone. Given my scenarios, this worked out to be the least time consuming solution. I needed to keep everything associated with zone the same- baseline systems configuration was already in place. Create Baseline model is a great resource, but I cannot use it because I need to evaluate a measure by measure analysis(Lighting, Ext wall, Roof etc). It would be great if the measure had components split up- like apply lighting only or HVAC only et |
2017-03-21 10:25:48 -0500 | asked a question | replacing osm geometry changes from one file to another Hi All, I have created a baseline model and proposed model in open studio. As usual, I have had to change geometry in the tool and am trying to match get the changes done in the baseline model too. Since, I have used the same parent file- same space names, thermal zone names, i hoped that copying the changes would be easy enough. I tried using import envelope and idf measure, but the zone equipment seems to have lost its association and crashes when the thermal zone or plant loop tabs are selected. Is there an alternate merge solution to this? |
2017-02-01 10:10:26 -0500 | answered a question | Space infiltration You should be able to find most of your questions answered in this documentation-http://bigladdersoftware.com/epx/docs/8-6/input-output-reference/. Open studio v1.14 uses Energy plus version 8.6 and uses same terminology as well. |
2016-11-29 14:05:45 -0500 | asked a question | how to add tranformer in open studio? I am looking to add an energy plus object 'ElectricLoadCenter:Transformer' |
2016-09-29 09:41:42 -0500 | commented answer | eQuest Geometry to EnergyPlus @Phylroy Lopez - has there been an update to this measure? |
2016-09-26 08:25:42 -0500 | commented answer | eQuest Geometry to EnergyPlus Has there been an update to this? I see this when I try to apply- Failed to Show Arguments Reason(s): Failed to compute arguments for measure: cannot load such file -- C:/Users/nlavu/OpenStudio/Measures/btap_equest_converter/../../../../lib/btap/lib/btap.rb |
2016-09-23 15:44:48 -0500 | received badge | ● Teacher (source) |
2016-09-23 15:42:00 -0500 | answered a question | eQuest Geometry to EnergyPlus Has there been an update to this? I see this when I try to apply- Failed to Show Arguments Reason(s): Failed to compute arguments for measure: cannot load such file -- C:/Users/nlavu/OpenStudio/Measures/btap_equest_converter/../../../../lib/btap/lib/btap.rb |
2016-09-15 12:31:55 -0500 | commented answer | Free cooling module on Chillers(Open Studio) Thank you Annie. Just to confirm- I believe in this approach you don't need the component override nodes since the control is CoolingSetpointOnOff. These inputs are only triggered when CoolingSetpointOnOffWithComponentOverride gets choosen. I do not have a chiller node on the condenser side(Air cooled chiller). So, the control type is restricted to CoolingSetpointOnOff. This strategy works fine in january but does not trigger even when the loop input to oat is ~25 F delta in december. This makes me think that this is not working as expected! In summation, works only10% of the potential hours! |