2019-11-21 03:20:35 -0500 | answered a question | Modelling Exhaust Air Heat Pump The heat pump in the image was designed to work only with fresh air. The red line doesn't make any sense to Design Build |
2019-03-29 01:56:35 -0500 | commented question | LED Build Specficiations for DesignBuilder DesignBuilder has some templates for different types of lamps (e.g. LED, T5, T8, incandescent etc.). Bear in mind that t |
2019-03-11 01:52:24 -0500 | commented question | Running simulation in design Builder As far as i know the limit for maximum 50 thermal zones applies only to the trial version. Go to "Help / Licence" to see |
2018-09-07 08:36:53 -0500 | commented answer | Please I’m a complete novice to TRNSYS, please how do I use it to calculate energy consumption of a building (lights, computers, HVAC) you can find tutorials on youtube |
2018-08-01 00:48:02 -0500 | commented answer | BREEAM methodology questions If i have it in my Proposed Building i use it in the BREEAM Best Practice Building as well. Otherwise i don't use it. |
2018-07-16 01:04:51 -0500 | answered a question | BREEAM methodology questions I follow the same procedure - this implies 2 models for the Best Practice building. However, in GN25 the asterix sign * |
2018-07-12 04:09:45 -0500 | commented question | BREEAM methodology questions I understand that the Best Practice building is the Actual Building (including interior and exterior shading; no modific |
2018-07-12 04:08:04 -0500 | commented question | BREEAM methodology questions I understand that the Best Practice building is the Actual Building (including interior and exterior shading) where you |
2018-07-12 04:07:54 -0500 | commented question | BREEAM methodology questions I understand that the Best Practice building is the Actual Building (including interior and exterior shading) where you |
2018-07-12 04:07:41 -0500 | commented question | BREEAM methodology questions I understand that the Best Practice building is the Actual Building (including interior and exterior shading) where you |
2018-06-27 00:35:46 -0500 | commented question | simulation without cooling or heating equipment From what i can tell the exterior temperature minimum is pretty high - this implies a lot of solar radiation as well. I |
2018-06-15 00:43:48 -0500 | answered a question | how design builder calculates daylight? You are looking in the wrong place. For a daylingting calculation go the Daylighting tab (bottom right corner of your pi |
2018-06-08 01:01:27 -0500 | commented answer | Heating and cooling system in the floor I'm not sure i understand. The heated floor/chilled ceiling are radiant surfaces as well. The advantage of "radiant surf |
2018-06-08 01:00:59 -0500 | commented answer | Heating and cooling system in the floor I'm not sure i understand. The heated floor/chilled ceiling are radiant surfaces as well. The advantage of "radiant surf |
2018-06-08 01:00:36 -0500 | commented answer | Heating and cooling system in the floor I'm not sure i understand. The heated floor/chilled ceiling are radiant surfaces as well. The advantage of "radiant surf |
2018-05-14 09:27:08 -0500 | commented question | zoning in design builder Go to the plenum and select it's floor. I'm guessing that the plenum floor has different layers than a regular floor. |
2018-05-14 05:24:54 -0500 | commented question | zoning in design builder can you share an image of your building (you can zoom in to the "problem" area) |
2018-05-14 01:17:44 -0500 | commented question | zoning in design builder Just make a 0.5m block between floors and assign it as plenum (Activity tab). After that verify the thickness of the flo |
2018-05-14 01:17:44 -0500 | received badge | ● Commentator |
2018-04-05 09:07:08 -0500 | commented question | EnergyPlus heat recovery from a zone to heat another zone The VRF system with heat recovery works in this way. More info here link text. It's not quite a hydronic system but has |
2018-03-30 05:35:54 -0500 | commented answer | Why the glass walls behave as opaque walls in the designbuilder ? "Glass-cellular sheet" is a wall material (opaque wall). In order to make an internal window: select the internal wall a |
2018-03-30 05:31:30 -0500 | commented answer | Why the glass walls behave as opaque walls in the designbuilder ? "Glass-cellular sheet" is a wall material (opaque wall). In order to make an internal window: select the internal walls |
2018-03-30 00:47:47 -0500 | commented question | Why the glass walls behave as opaque walls in the designbuilder ? I never had this problem. Can you attach an image with the floor daylighting results. |
2018-03-21 09:48:08 -0500 | commented answer | VRF air cooled system compared to water cooled VRF system I get your point and you are right, different curves should be used. Just for test - I have the same issue (water fed V |
2018-03-15 08:19:35 -0500 | answered a question | window-films designbuilder The simplest way is to go to "Glazing type", chose "2-Simple" definition method and at "Light transmission" enter the co |
2018-03-13 08:15:33 -0500 | edited answer | Heating and cooling system in the floor In the latest version you have "radiant surface" which can be used both for heating and cooling. More info here: link te |
2018-03-13 08:13:40 -0500 | answered a question | Heating and cooling system in the floor In the latest version you have "radiant surface" which can be used both for heating and cooling. More info here: link te |
2018-03-06 00:56:13 -0500 | answered a question | Can PPD be directly generated by the program in Design Builder? DesignBuilder shows only the PMV values in outputs. For the PPD values you'll have to use "DesignBuilder Result Viewer" |
2018-02-28 00:56:31 -0500 | answered a question | Schedules Designbuilder You have to export the database with the custom schedules; HVAC templates; etc. File / Export / Export library data Th |
2018-01-15 01:28:02 -0500 | answered a question | why does not the airflow graph appear in the simulation result in design builder? Make sure that the "Fresh air supply" box is checked in the simulation tab. |
2018-01-08 00:47:00 -0500 | commented question | How to model latent heat gain in TRNSYS As far as i remember there is an option in the gains menu where you can specify the latent fraction. |
2017-12-15 01:30:40 -0500 | edited answer | How to simulate BIPV on sun shade in DesignBuider? Construct your PV panels using the tool marked with yellow. After that double click on the PV panes and enter its effici |
2017-12-15 01:30:21 -0500 | edited answer | How to simulate BIPV on sun shade in DesignBuider? Construct your PV panels using the tool marked with yellow. After that double click on the PV panes and enter its effici |
2017-12-15 01:28:09 -0500 | answered a question | How to simulate BIPV on sun shade in DesignBuider? Construct your PV panels using the tool marked with yellow. After that double click on the PV panes and enter its effici |
2017-11-09 01:17:00 -0500 | answered a question | Connection of multiple cooling towers, chillers and AHUs with zone You should watch their tutorials. What you're looking for can be found in Detailed HVAC chapter. |
2017-10-09 00:58:11 -0500 | commented question | if Simcad can be installed in trnsys16 to build a complicated architectural model? It’s been a while since I used Trnsys 16, however I don’t recall a 3D modelling option for it. You have to manually cons |
2017-10-09 00:58:03 -0500 | commented question | if Simcad can be installed in trnsys16 to build a complicated architectural model? It’s been a while since I used Trnsys 16, however I don’t recall a 3D modelling option for it. You have to manually cons |
2017-10-04 01:16:43 -0500 | commented question | How to model air heater with the Design Builder? You can use the fan coil units template with gas boiler and chiller. Then turn off the chiller (set the schedule to off |
2017-09-12 09:33:02 -0500 | answered a question | Resistance of wall The short answer- you can’t because EnergyPlus calculates 1D heat transfer. To include a wall with materials in parallel |
2017-06-28 07:16:42 -0500 | answered a question | how to model this wall in TRNBUILD? First check your architectural drawings for some clues on the type of wall you are modelling (e.g. if you model a house |
2017-06-07 08:57:57 -0500 | received badge | ● Critic (source) |
2017-06-06 00:52:41 -0500 | answered a question | How do I find the best solar collector slope for Sydney? The easiest way is to run a parametric simulation with SAM (System Advisor Model). With a few clicks you can find the o |
2017-05-24 09:09:53 -0500 | answered a question | SketchUp Make drawing formats for OpenStudio geometry The option to import dwg/dxf files is available only in SketchupPro (you have to buy it). More details here: link text |
2017-05-11 08:17:27 -0500 | commented question | Building modelling in TRNSYS (Type 56) : ASHRAE 2013 Design day as Weather Data for HVAC sizing It’s been a while since I used Trnsys, but I don’t remember using design days. I obtained the heating/cooling load by r |
2017-05-05 04:42:19 -0500 | received badge | ● Editor (source) |
2017-05-05 04:42:19 -0500 | edited answer | Dry cooler modelling For DesignBuilder free-cooling heat exchanger go to HVAC system and select waterside economizer template. Replace the |
2017-05-05 04:40:02 -0500 | edited answer | Dry cooler modelling For DesignBuilder free-cooling heat exchanger go to HVAC system and select waterside economizer template. Replace the |
2017-05-05 01:56:05 -0500 | answered a question | Dry cooler modelling For DesignBuilder free-cooling heat exchanger go to HVAC system and select waterside economizer template. Replace the |
2017-05-03 00:47:03 -0500 | answered a question | Origins of 4 Pa reference pressure for infiltration... As I recall from my collage course: 4 Pa is the average pressure difference between indoor and outdoor (in mild wind con |