2019-11-21 03:20:35 -0500 answered a question Modelling Exhaust Air Heat Pump

The heat pump in the image was designed to work only with fresh air. The red line doesn't make any sense to Design Build

2019-03-29 01:56:35 -0500 commented question LED Build Specficiations for DesignBuilder

DesignBuilder has some templates for different types of lamps (e.g. LED, T5, T8, incandescent etc.). Bear in mind that t

2019-03-11 01:52:24 -0500 commented question Running simulation in design Builder

As far as i know the limit for maximum 50 thermal zones applies only to the trial version. Go to "Help / Licence" to see

2018-09-07 08:36:53 -0500 commented answer Please I’m a complete novice to TRNSYS, please how do I use it to calculate energy consumption of a building (lights, computers, HVAC)

you can find tutorials on youtube

2018-08-01 00:48:02 -0500 commented answer BREEAM methodology questions

If i have it in my Proposed Building i use it in the BREEAM Best Practice Building as well. Otherwise i don't use it.

2018-07-16 01:04:51 -0500 answered a question BREEAM methodology questions

I follow the same procedure - this implies 2 models for the Best Practice building. However, in GN25 the asterix sign *

2018-07-12 04:09:45 -0500 commented question BREEAM methodology questions

I understand that the Best Practice building is the Actual Building (including interior and exterior shading; no modific

2018-07-12 04:08:04 -0500 commented question BREEAM methodology questions

I understand that the Best Practice building is the Actual Building (including interior and exterior shading) where you

2018-07-12 04:07:54 -0500 commented question BREEAM methodology questions

I understand that the Best Practice building is the Actual Building (including interior and exterior shading) where you

2018-07-12 04:07:41 -0500 commented question BREEAM methodology questions

I understand that the Best Practice building is the Actual Building (including interior and exterior shading) where you

2018-06-27 00:35:46 -0500 commented question simulation without cooling or heating equipment

From what i can tell the exterior temperature minimum is pretty high - this implies a lot of solar radiation as well. I

2018-06-15 00:43:48 -0500 answered a question how design builder calculates daylight?

You are looking in the wrong place. For a daylingting calculation go the Daylighting tab (bottom right corner of your pi

2018-06-08 01:01:27 -0500 commented answer Heating and cooling system in the floor

I'm not sure i understand. The heated floor/chilled ceiling are radiant surfaces as well. The advantage of "radiant surf

2018-06-08 01:00:59 -0500 commented answer Heating and cooling system in the floor

I'm not sure i understand. The heated floor/chilled ceiling are radiant surfaces as well. The advantage of "radiant surf

2018-06-08 01:00:36 -0500 commented answer Heating and cooling system in the floor

I'm not sure i understand. The heated floor/chilled ceiling are radiant surfaces as well. The advantage of "radiant surf

2018-05-14 09:27:08 -0500 commented question zoning in design builder

Go to the plenum and select it's floor. I'm guessing that the plenum floor has different layers than a regular floor.

2018-05-14 05:24:54 -0500 commented question zoning in design builder

can you share an image of your building (you can zoom in to the "problem" area)

2018-05-14 01:17:44 -0500 commented question zoning in design builder

Just make a 0.5m block between floors and assign it as plenum (Activity tab). After that verify the thickness of the flo

2018-05-14 01:17:44 -0500 received badge  Commentator
2018-04-05 09:07:08 -0500 commented question EnergyPlus heat recovery from a zone to heat another zone

The VRF system with heat recovery works in this way. More info here link text. It's not quite a hydronic system but has

2018-03-30 05:35:54 -0500 commented answer Why the glass walls behave as opaque walls in the designbuilder ?

"Glass-cellular sheet" is a wall material (opaque wall). In order to make an internal window: select the internal wall a

2018-03-30 05:31:30 -0500 commented answer Why the glass walls behave as opaque walls in the designbuilder ?

"Glass-cellular sheet" is a wall material (opaque wall). In order to make an internal window: select the internal walls

2018-03-30 00:47:47 -0500 commented question Why the glass walls behave as opaque walls in the designbuilder ?

I never had this problem. Can you attach an image with the floor daylighting results.

2018-03-21 09:48:08 -0500 commented answer VRF air cooled system compared to water cooled VRF system

I get your point and you are right, different curves should be used. Just for test - I have the same issue (water fed V

2018-03-15 08:19:35 -0500 answered a question window-films designbuilder

The simplest way is to go to "Glazing type", chose "2-Simple" definition method and at "Light transmission" enter the co

2018-03-13 08:15:33 -0500 edited answer Heating and cooling system in the floor

In the latest version you have "radiant surface" which can be used both for heating and cooling. More info here: link te

2018-03-13 08:13:40 -0500 answered a question Heating and cooling system in the floor

In the latest version you have "radiant surface" which can be used both for heating and cooling. More info here: link te

2018-03-06 00:56:13 -0500 answered a question Can PPD be directly generated by the program in Design Builder?

DesignBuilder shows only the PMV values in outputs. For the PPD values you'll have to use "DesignBuilder Result Viewer"

2018-02-28 00:56:31 -0500 answered a question Schedules Designbuilder

You have to export the database with the custom schedules; HVAC templates; etc. File / Export / Export library data Th

2018-01-15 01:28:02 -0500 answered a question why does not the airflow graph appear in the simulation result in design builder?

Make sure that the "Fresh air supply" box is checked in the simulation tab.

2018-01-08 00:47:00 -0500 commented question How to model latent heat gain in TRNSYS

As far as i remember there is an option in the gains menu where you can specify the latent fraction.

2017-12-15 01:30:40 -0500 edited answer How to simulate BIPV on sun shade in DesignBuider?

Construct your PV panels using the tool marked with yellow. After that double click on the PV panes and enter its effici

2017-12-15 01:30:21 -0500 edited answer How to simulate BIPV on sun shade in DesignBuider?

Construct your PV panels using the tool marked with yellow. After that double click on the PV panes and enter its effici

2017-12-15 01:28:09 -0500 answered a question How to simulate BIPV on sun shade in DesignBuider?

Construct your PV panels using the tool marked with yellow. After that double click on the PV panes and enter its effici

2017-11-09 01:17:00 -0500 answered a question Connection of multiple cooling towers, chillers and AHUs with zone

You should watch their tutorials. What you're looking for can be found in Detailed HVAC chapter.

2017-10-09 00:58:11 -0500 commented question if Simcad can be installed in trnsys16 to build a complicated architectural model?

It’s been a while since I used Trnsys 16, however I don’t recall a 3D modelling option for it. You have to manually cons

2017-10-09 00:58:03 -0500 commented question if Simcad can be installed in trnsys16 to build a complicated architectural model?

It’s been a while since I used Trnsys 16, however I don’t recall a 3D modelling option for it. You have to manually cons

2017-10-04 01:16:43 -0500 commented question How to model air heater with the Design Builder?

You can use the fan coil units template with gas boiler and chiller. Then turn off the chiller (set the schedule to off

2017-09-12 09:33:02 -0500 answered a question Resistance of wall

The short answer- you can’t because EnergyPlus calculates 1D heat transfer. To include a wall with materials in parallel

2017-06-28 07:16:42 -0500 answered a question how to model this wall in TRNBUILD?

First check your architectural drawings for some clues on the type of wall you are modelling (e.g. if you model a house

2017-06-07 08:57:57 -0500 received badge  Critic (source)
2017-06-06 00:52:41 -0500 answered a question How do I find the best solar collector slope for Sydney?

The easiest way is to run a parametric simulation with SAM (System Advisor Model). With a few clicks you can find the o

2017-05-24 09:09:53 -0500 answered a question SketchUp Make drawing formats for OpenStudio geometry

The option to import dwg/dxf files is available only in SketchupPro (you have to buy it). More details here: link text

2017-05-11 08:17:27 -0500 commented question Building modelling in TRNSYS (Type 56) : ASHRAE 2013 Design day as Weather Data for HVAC sizing

It’s been a while since I used Trnsys, but I don’t remember using design days. I obtained the heating/cooling load by r

2017-05-05 04:42:19 -0500 received badge  Editor (source)
2017-05-05 04:42:19 -0500 edited answer Dry cooler modelling

For DesignBuilder free-cooling heat exchanger go to HVAC system and select waterside economizer template. Replace the

2017-05-05 04:40:02 -0500 edited answer Dry cooler modelling

For DesignBuilder free-cooling heat exchanger go to HVAC system and select waterside economizer template. Replace the

2017-05-05 01:56:05 -0500 answered a question Dry cooler modelling

For DesignBuilder free-cooling heat exchanger go to HVAC system and select waterside economizer template. Replace the

2017-05-03 00:47:03 -0500 answered a question Origins of 4 Pa reference pressure for infiltration...

As I recall from my collage course: 4 Pa is the average pressure difference between indoor and outdoor (in mild wind con