2020-05-21 14:20:58 -0500 | commented answer | Rated Supply Fan Power Per Volume Flow Rate that is great to know! thanks for the clarification Aaron! |
2020-05-20 17:13:29 -0500 | commented answer | Rated Supply Fan Power Per Volume Flow Rate Thanks Ag, you said - "It is worth to note both values do not directly affect simulations results in term of temperatur |
2020-05-20 13:02:18 -0500 | edited question | Rated Supply Fan Power Per Volume Flow Rate Rated Supply Fan Power Per Volume Flow Rate What is "Rated Supply Fan Power Per Volume Flow Rate" it is in the openstudi |
2020-05-20 12:56:37 -0500 | edited question | Rated Supply Fan Power Per Volume Flow Rate Rated Supply Fan Power Per Volume Flow Rate What is "Rated Supply Fan Power Per Volume Flow Rate" it is in the openstudi |
2020-05-20 12:56:10 -0500 | asked a question | Rated Supply Fan Power Per Volume Flow Rate Rated Supply Fan Power Per Volume Flow Rate What is "Rated Supply Fan Power Per Volume Flow Rate" it is in the openstudi |
2020-04-02 10:50:04 -0500 | commented answer | How to model DX cooling with VAV FPB boxes? If you want it to mimic a VAV box, you could set the fan power of the terminal to zero. You will have to be careful thou |
2020-04-02 10:47:31 -0500 | commented answer | How to model DX cooling with VAV FPB boxes? If you want it to mimic a VAV box, you could set the fan power of the terminal to zero. |
2020-04-02 10:42:35 -0500 | answered a question | How to model DX cooling with VAV FPB boxes? I am not sure if you can add DX directly to a VAV box in EnergyPlus, but you could add a ZoneHVAC:WaterToAirHeatPump, wh |
2020-03-02 12:33:04 -0500 | commented answer | Can the AirFlowNetwork handle two AirLoops serving the same zone? Can you use a single DOAS ERV Airloop and add a ZoneHVAC:PackagedTerminalHeatPump to each zone? The DOAS could be used f |
2020-03-02 12:06:12 -0500 | answered a question | AirflowNetwork and Construction:AirBoundary interaction? Are you serving multiple zones with both air loops? If you are just serving one zone you might be able to use one of the |
2019-10-13 09:19:25 -0500 | answered a question | Outside Dry bulb Temperature is 32F on Summer Design Day That is odd. Are you looking at the .epw weather file or the .ddy design day file? The design day file should be used to |
2018-12-20 16:31:16 -0500 | commented question | Energy Plus LoadProfile:Plant from Schedule:File issues @JulienMarrec I have placed the IDF and CSV in the link below. I had this model running with a smaller load. As soon as |
2018-12-20 15:55:27 -0500 | edited question | Energy Plus LoadProfile:Plant from Schedule:File issues Energy Plus LoadProfile:Plant from Schedule:File issues I am creating load profiles for a plant model using an 8760 csv |
2018-12-18 17:52:50 -0500 | edited question | Energy Plus LoadProfile:Plant from Schedule:File issues Energy Plus LoadProfile:Plant from Schedule:File issues I am creating load profiles for a plant model using an 8760 csv |
2018-12-18 17:52:36 -0500 | edited question | Energy Plus LoadProfile:Plant from Schedule:File issues Energy Plus LoadProfile:Plant from Schedule:File issues I am creating load profiles for a plant model using an 8760 csv |
2018-12-18 15:06:12 -0500 | asked a question | Energy Plus LoadProfile:Plant from Schedule:File issues Energy Plus LoadProfile:Plant from Schedule:File issues I am creating load profiles for a plant model using an 8760 csv |
2018-09-14 17:43:37 -0500 | commented answer | how do I export Space name and SpaceType name into csv with an OpenStudio measure? this is great. thank you! Although I had to flip your if statement to get it to work space_hash = [] model.getSpaces.ea |
2018-07-30 14:49:30 -0500 | asked a question | Decoupled Cooling With Economizer Option OpenStudio Decoupled Cooling With Economizer Option OpenStudio I would like to test a building option which uses chilled beams, but |
2018-03-06 20:02:02 -0500 | received badge | ● Popular Question (source) |
2017-12-11 09:15:49 -0500 | commented answer | VAV reheat coil behaving unexpectedly and leading to unmet hours Hi Liam, I have notice this problem as well. From my experience, the reheat coils are sized to heat only the air require |
2017-07-14 18:19:37 -0500 | received badge | ● Self-Learner (source) |
2017-07-14 16:36:57 -0500 | edited answer | OS Crashes When Opening Hydronic Loop I figured out the issue. I was deleting a cooling coil from the text editor without deleting the associated inlet and ou |
2017-07-14 14:04:07 -0500 | received badge | ● Editor (source) |
2017-07-14 14:04:07 -0500 | edited answer | OS Crashes When Opening Hydronic Loop Now I am getting the same error when I run a measure to add VAV boxes and reheat for multiple zones. This measure worked |
2017-07-14 11:39:12 -0500 | edited question | OS Crashes When Opening Hydronic Loop OS Crashes When Opening Hydronic Loop Every time I open the hot water loop in my model it crashes. Any ideas as to why t |
2017-07-14 11:39:07 -0500 | received badge | ● Teacher (source) |
2017-07-14 11:37:57 -0500 | answered a question | OS Crashes When Opening Hydronic Loop I figured out the issue. I was deleting a cooling coil from the text editor without deleting the associated inlet and ou |
2017-07-14 10:56:50 -0500 | commented question | OS Crashes When Opening Hydronic Loop I am using version 2.1. What information about the history of the model will be helpful? |
2017-07-13 19:23:43 -0500 | asked a question | OS Crashes When Opening Hydronic Loop OS Crashes When Opening Hydronic Loop Every time I open the hot water loop in my model it crashes. Any ideas as to why t |
2017-02-13 17:06:08 -0500 | asked a question | EnergyPlus SQL Query for SHGC I have been using DB browser to query EnergyPlus inputs and outputs for information. However, I can't seem to find glazing SHGC and visible transmittance included anywhere. It is shown in the output HTML table, so I assume it is included somewhere in the SQL file. Can anyone point me to the table which includes this information in the SQL file? |
2017-01-13 14:53:13 -0500 | asked a question | Heat Pump Water to Water Controls I am trying to model a chiller plant for a building with heat recovery chillers and air cooled chiller. The heat recovery chillers (water to water heat pumps in OS) need to turn on first on the cooling side but regulate to the heating demand. In Summer months when more cooling is required the hot water loop overheats from the heat recovery chiller dumping too much heat into the loop. Error is shown below. Does anyone have a suggested work around to this issue? |
2016-12-14 13:52:21 -0500 | commented answer | VAV Reheat Coil Sizing Thank you for the feed back. I guess the work around is providing a dummy load in the space on the heating design day. Is there no way to include a minimum ventilation reheat load on the heating design day? |
2016-12-14 13:49:13 -0500 | received badge | ● Supporter (source) |
2016-12-12 22:32:10 -0500 | asked a question | VAV Reheat Coil Sizing I am having a problem with heating unmet hours on a VAV system that appears to be an issue with the reheat coil. The problem only occurs in internal zones where the heating load on the coil is due to reheat only. On exterior spaces where there is envelope load there is not problem. The issue is most obvious in large spaces where ACH are high compared to internal loads. The VAV box is supplying air near 55F and not reheating to meet the temperature setpoint. It appear that the coil is not being sized for the reheat load and only for whatever exterior load exists which is none. Here is my sizing:zone object C:\fakepath\Capture.PNG Here is my sizing:system object C:\fakepath\Capture1.PNG The loop set up is simple with a HW loop operating at 130F with a 40F delta T serving the air loop. Does anyone have insight into why the coil is being sized incorrectly and I am seeing unmet hours? |
2016-11-11 13:13:38 -0500 | received badge | ● Student (source) |
2016-11-11 12:06:02 -0500 | asked a question | OSM Diagnostic Script Doesn't Resave File I want to run the OSM diagnostics to remove some very degenerate surfaces. I've done this before and usually the script saves a new file called "filename_diagnostics.osm" after running. The last few times I've tried it does save anything after running. Any ideas on how I can get it to resave the file again so I can use the changes it makes? Thank you! |