First time here? Check out the Help page!
2017-08-09 14:38:23 -0500 | answered a question | how to build EnergyPlus IDF file in Google SketchUp? Be sure you use "save as energy plus input file and "save as" with the extension .idf in the file name. C:\fake |
2017-08-09 14:25:26 -0500 | answered a question | Help about data of EPW of Loja-Ecuador Do you need the meteorological data set? Or you already have it and need clarification as to the format? |
2017-05-19 13:49:08 -0500 | commented answer | is it possible to acheave 100% relative humidity at the outlet of an evaporative cooler by precooling the air about 2 or 3 degrees? The efficiency of an evaporative cooler is by definition ; e= (tdi - tdo) / (tdi - twi) tdi= Dry bulb temperature at i |
2017-05-19 13:48:52 -0500 | commented answer | is it possible to acheave 100% relative humidity at the outlet of an evaporative cooler by precooling the air about 2 or 3 degrees? The efficiency of an evaporative cooler is by definition ; e= (tdi - tdo) / (tdi - twi) tdi= Dry bulb temperature at i |
2017-05-19 13:48:32 -0500 | commented answer | is it possible to acheave 100% relative humidity at the outlet of an evaporative cooler by precooling the air about 2 or 3 degrees? The efficiency of an evaporative cooler is by definition ; e= (tdi - tdo) / (tdi - twi) tdi= Dry bulb temperature at in |
2017-05-18 11:47:47 -0500 | answered a question | is it possible to acheave 100% relative humidity at the outlet of an evaporative cooler by precooling the air about 2 or 3 degrees? Even if you do not precool,you would need a 100% efficient device. |
2017-03-23 14:50:07 -0500 | answered a question | How to simulate a green wall in design builder with green roof feature? Maybe this can give you insight: Thermal simulation of a double skin façade with plants Silvana Flores Larsena*, Celina Filippínb, Graciela Lesinoa Energy Procedia 57 ( 2014 ) 1763 – 1772 |
2017-03-21 19:49:47 -0500 | answered a question | How do you convert an imported skp into an OpenStudio Space? For simple buildings and Legacy Open Studio plugin, I have done this: In the sketchup file, I creat a new energy plus zone, and simply copy the whole building to the new zone. Once I am sure everything is in the new zone, I delete the original drawing and save as... new name.idf Hope it helps |
2017-03-21 19:46:25 -0500 | received badge | ● Critic (source) |
2017-02-20 15:37:30 -0500 | answered a question | Is possible to calculate the heating rate using COMPACT HVAC:ZONE:PURCHASED AIR in Energy Plus v. 8.6? Ideal Load Air System is a concept totally equivalent to purchased air. Check the input output reference manual. You can use the HVACTemplate objects for convenience: Or the ZoneHVAC:IdealLoadsAirSystem directly. |
2017-02-14 12:18:49 -0500 | answered a question | Can you put a light shelf on the inside? THe input output Reference handbook can be useful. This is described under 1.13.10 DaylightingDevice:Shelf. And it seems that yes, you can. Regards. |
2017-02-14 12:14:19 -0500 | answered a question | Weather data for Mexico. I have Meteonorm files for many locations in the country. If Meteonorm files are good enough for you, I can send the files for your locations. Just let me know. Regards. Ricardo |
2017-01-31 13:09:59 -0500 | answered a question | How can I use .stat / .audit file format? It is just plain ACII text, you should be able to open with any text editor, or if you use Windows, the notepad is good enough. You can also open with a spreadsheet program so you can make any calculations. Good Luck! |
2017-01-26 13:19:19 -0500 | answered a question | Why a high tickness wall generates more discomfort? Do you have internal gains? Heat flow from internal gains going to the outside is retarded by such big thicness, as well as external heat flow does. |
2017-01-26 13:11:21 -0500 | received badge | ● Enthusiast |
2017-01-24 14:52:17 -0500 | answered a question | Drawing Surfaces in the SketchUp Plugin Did you create a new energy plus zone? Any thing that is drawn outside an energy plus zone is not recognized in SU as an EP object. C:\fakepath\Captura.PNG |
2016-11-30 12:54:48 -0500 | answered a question | Extra surfaces created in IDF file but do not show up in Sketchup I have had this problem and I was told that there is not yet a plugin for SU that works with E+ 8.4 or 8.5. What I do is to create the model in E+ and then open in SU just to check geometry, but do not save it in su as idf. But my projects are smaller than yours. |
2016-11-22 12:47:45 -0500 | answered a question | unable to open the file associated with and ASSIGNED logical unit number Maybe the path for the IAM file is not correctly set in the "External Files" tab of the proforma. |
2016-11-04 13:07:03 -0500 | answered a question | Thick wall partly penetrating a zone I think you could split the indoor zone into two zones, divided in the middle by two walls. 1) The thick wall, 2) An air wall. |
2016-11-03 17:39:53 -0500 | received badge | ● Editor (source) |
2016-11-03 14:56:39 -0500 | answered a question | create dll file from fortran code exported from TRNSYS to create a new type There are few vesions of FORTAN compilers that can be useful. For reasons unknown to me, many fortran compilers won' t work. I have used compaq visual fortran (CVF) and worked fine for me. Unfortunately, I think CVF is not longer distributed. Try to find a computer that has CVF to compile your component. |
2016-10-17 12:08:52 -0500 | answered a question | Where can I find (such as database) the R-values of different materials? The U value takes into the account the film coefficients on the outside and the inside. For complex walls and roofs, with thermal bridges, there is a publication of ASHRAE that lists numerous structures with their U values, sorry I dont have the reference at hand. |
2016-09-23 15:18:11 -0500 | answered a question | I've noticed duplicated zones and surfaces, when using SketchUp 2016 and OpenStudio 10.9.0. Does anyone have the same problem and an idea how to solve it? If you are using e+ 8.5, and Legacy OS, there is not yet a plugin available. I read somewhere else that it could be available by October. I have the very same problem, so I decided to work with e+ 8.3 |
2016-09-23 12:59:30 -0500 | answered a question | What is the best way to create an EPW weather file from real data? There is a programm free to download called "Elements" that allows you to create weather files, or modify existingweather files, here is the link . Hope it helps. http://bigladdersoftware.com/projects... |
2016-08-11 15:10:53 -0500 | received badge | ● Supporter (source) |
2016-07-20 11:53:48 -0500 | answered a question | How we can assign the tilt of PV array in EnergyPlus? You need to create a titled surface in "shading: building" and link this surface in " generator:photovoltaic " |
2016-06-02 11:40:16 -0500 | received badge | ● Teacher (source) |
2016-06-01 22:59:49 -0500 | answered a question | Energyplus 8.5 crash I have had this problem a few times. My file was located too deep in the folder structure, and/or the names of files or directory were too long. Try relocating/renaming your idf. That worked for me, hope it does for you. |