2022-10-12 09:36:09 -0500 | commented answer | liquid desiccant dehumidification @djaouadiamir@gmail.com Hi, my research paper has been published in International Jounral of Refrigeration titled " |
2022-10-12 09:33:02 -0500 | commented answer | liquid desiccant dehumidification @djaouadiamir@gmail.com Hi, my research paper has been published in International Jounral of Refrigeration titled "Pe |
2022-02-22 01:33:22 -0500 | received badge | ● Popular Question (source) |
2022-01-17 07:42:02 -0500 | edited question | fan schedule not working fan schedule not working I'm doing research about heat recovery in data center, sensible heat from datacenter was tranpo |
2022-01-10 22:23:33 -0500 | commented question | fan schedule not working Thanks @Aaron Boranian, question has been revised. |
2022-01-10 22:22:46 -0500 | edited question | fan schedule not working fan schedule not working I'm doing research about heat recovery in data center, sensible heat from datacenter was tranpo |
2022-01-10 22:20:34 -0500 | edited question | fan schedule not working fan schedule not working I'm doing research about heat recovery in data center, sensible heat from datacenter was tranpo |
2022-01-10 05:00:26 -0500 | asked a question | fan schedule not working fan schedule not working I'm doing research about heat recovery in data center, sensible heat from datacenter was tranpo |
2021-12-05 08:56:23 -0500 | commented answer | VAV Reheat with Humidifer I want to konw if EnergyPlus could simulate two AirLoops in one zone, if not, is theZoneHVAC:EvaporativeCoolerUnit a goo |
2021-12-05 08:46:40 -0500 | marked best answer | VAV Reheat with Humidifer I'm modeling humidity control of Data Center in Office Building. RH need to be controlled as 40%~60% in Data Center, 50% and lower in other zones occupied. A VAV reheat system control every floor, for 5 zones occupied, and 1 data center. Desiccant system has been set in every VAV airloop to dehumidification, but for terminal, only one zone(data center) need humidifer, but when I put it after reheat coil of data center, some errors occured. So how can I reach this target? |
2021-12-05 08:46:25 -0500 | commented answer | VAV Reheat with Humidifer Thanks, that's what I'm looking for. |
2021-12-05 00:24:01 -0500 | asked a question | VAV Reheat with Humidifer VAV Reheat with Humidifer I'm modeling humidity control of Data Center in Office Building. RH need to be controlled as |
2021-11-05 01:31:46 -0500 | commented answer | Heating Loads in dehumidification model Thansk, It is the link to my IDF. (https://www.dropbox.com/s/131yvxdmm8qdhh5/ASHRAE90.1_ApartmentHighRiseDesiccantWheel. |
2021-11-05 01:31:46 -0500 | received badge | ● Commentator |
2021-11-05 01:30:24 -0500 | edited question | Desiccant dehumidifer system problem Desiccant dehumidifer system problem Hi, I'm doing simulation with desiccant wheel system in hot and humid area to verif |
2021-11-05 01:16:43 -0500 | edited question | Desiccant dehumidifer system problem Desiccant dehumidifer system problem Hi, I'm doing simulation with desiccant wheel system in hot and humid area to verif |
2021-11-04 09:04:50 -0500 | asked a question | Desiccant dehumidifer system problem Desiccant dehumidifer system problem Hi, I'm doing simulation with desiccant wheel system in hot and humid area to verif |
2021-11-03 00:54:07 -0500 | commented answer | Heating Loads in dehumidification model Thanks for your answer, but heating coils are both DX single speed with a similar COP. Reheat/Regen coils were electric. |
2021-11-03 00:53:26 -0500 | edited question | Heating Loads in dehumidification model Heating Loads in dehumidification model I'm researching RH control between split air conditioning and desiccant wheel, b |
2021-11-03 00:52:25 -0500 | edited question | Heating Loads in dehumidification model Heating Loads in dehumidification model I'm researching RH control between split air conditioning and desiccant wheel, b |
2021-11-03 00:14:48 -0500 | commented answer | Heating Loads in dehumidification model Thanks for your answer, but heating coils are both DX single speed with a similar COP. |
2021-11-01 22:19:21 -0500 | asked a question | Heating Loads in dehumidification model Heating Loads in dehumidification model I'm researching RH control between split air conditioning and desiccant wheel, b |
2021-09-25 21:20:56 -0500 | asked a question | Relative humidity unmet in desiccant wheel system Relative humidity unmet in desiccant wheel system My DesiccantDehumifierWithCompanionCoilSystem, objects copy from examp |
2021-09-01 02:24:23 -0500 | edited question | Split air conditioner humidity control Split air conditioner humidity control I'm using HVACTemplate:System:UnitarySystemand HVACTemplate:Zone:Unitaryto build |
2021-09-01 02:24:18 -0500 | received badge | ● Organizer (source) |
2021-09-01 02:23:02 -0500 | received badge | ● Citizen Patrol (source) |
2021-09-01 01:50:30 -0500 | asked a question | Split air conditioner humidity control Split air conditioner humidity control I'm using HVACTemplate:System:UnitarySystemand HVACTemplate:Zone:Unitaryto build |
2021-05-09 22:24:54 -0500 | received badge | ● Enthusiast |
2021-04-01 21:51:35 -0500 | commented answer | Using FMU parser.exe Thanks, Julien! It must type C:\EnergyPlusV9-2-0\PreProcess\FMUParser\parser first and then add the command code. It hel |
2021-04-01 21:45:02 -0500 | marked best answer | Using FMU parser.exe How to use FMU parser.exe? I have try it by ExternalInterfacesApplicationGuide step by step. But it still doesn't work In windows command interface enter:-printidf or other. I'll appreciate if there is some tutorial in detail. I use Energyplus 9.2.0 now. |
2021-04-01 04:48:53 -0500 | commented question | Using FMU parser.exe Yes, I have typed it.But it seems no feedback. |
2021-03-31 02:30:44 -0500 | edited question | Using FMU parser.exe Using FMU parser.exe How to use FMU parser.exe? I have try it by ExternalInterfacesApplicationGuide step by step. But it |
2021-03-31 02:29:37 -0500 | asked a question | Using FMU parser.exe Using FMU parser.exe How to use FMU parser.exe? I have try it by ExternalInterfacesApplicationGuide step by step. But it |
2021-01-19 20:07:31 -0500 | marked best answer | liquid desiccant dehumidification I kown that Energyplus can set general dehumidification system, include cooling dehumidification and solid desiccant dehumidification. I'm studying the energy consumption of liquid desiccant dehumidification. So how to build this model in Energyplus? |
2021-01-19 20:07:31 -0500 | received badge | ● Scholar (source) |
2021-01-18 02:31:54 -0500 | commented answer | liquid desiccant dehumidification So should I use dymola software?Which co-simulation software(modelica) is more suitable for LDAC?Dymola, simulationX etc |
2021-01-18 01:42:10 -0500 | commented answer | liquid desiccant dehumidification So should I use dymola software?Which co-simulation software(modelica) is more suitable for LDAC?Thanks!TAT |
2021-01-17 23:46:55 -0500 | commented answer | liquid desiccant dehumidification So should I use dymola software? It can connect to Matlab/simulink which BCVTB can also do.At the same time, functional |
2021-01-17 02:37:10 -0500 | asked a question | liquid desiccant dehumidification liquid desiccant dehumidification I kown that Energyplus can set general dehumidification system, include cooling dehumi |
2020-12-29 22:22:38 -0500 | commented answer | Energyplus connection error to zone I'll check it. Maybe it's hard. Thanks Aaron! |
2020-12-29 22:18:43 -0500 | commented question | Energyplus connection error to zone Thanks, jason. How can I know that I have a well-formed HVAC system? |
2020-12-27 00:08:19 -0500 | asked a question | Energyplus connection error to zone Energyplus connection error to zone My model can run completely, but when I see svg file. It's not a good connection.Lik |
2020-12-03 20:39:52 -0500 | received badge | ● Supporter (source) |