2022-06-10 08:24:13 -0500 | received badge | ● Popular Question (source) |
2021-03-02 12:51:11 -0500 | marked best answer | E+ VRF model heat recovery mode curves The E+ model for 'airconditioner:variablerefrigerantflow' does not have defaults for the following curves: , !- Heat Recovery Cooling Capacity Modifier Curve Name , !- Heat Recovery Cooling Energy Modifier Curve Name , !- Heat Recovery Heating Capacity Modifier Curve Name , !- Heat Recovery Heating Energy Modifier Curve Name Can someone recommend sources/references for these? |
2020-12-21 08:33:29 -0500 | commented answer | Example EMS code for PlantComponent:UserDefined Thank you for your answer. This is very helpful. |
2020-12-18 18:13:23 -0500 | asked a question | Example EMS code for PlantComponent:UserDefined Example EMS code for PlantComponent:UserDefined Hello, Is there example Erl code somewhere for an EMS PlantComponent:Use |
2020-07-30 15:39:06 -0500 | marked best answer | Default minimum outdoor temperature for DX coils The current minimum outdoor temperature for compressor operation for EnergyPlus objects 'Coil:Heating:DX:VariableSpeed' and 'AirConditioner:VariableRefrigerantFlow' is -20 DegC. The current cold-climate heat pump technology can operate easily down to -25 DegC. Ideally if this temperature can be allowed to drop to -30 DegC. What is the best way to request this kind of change in EnergyPlus? This is really not a feature request. It's more of minor code change. Is there a web link someone can share for entering this request for change in e+? |
2020-07-30 15:39:06 -0500 | received badge | ● Scholar (source) |
2020-07-30 15:37:44 -0500 | answered a question | VRF System in Cold Climates After you've added the VRF terminal unit to the zone, you can then add another object (such as baseboards or unit heater |
2020-07-30 15:32:13 -0500 | commented question | Heat Pump Minimum Inlet Air Temperature for Compressor Operation I have not checked this with the "WaterHeater:HeatPump" object, but you can try and take the IDF file generated by OS an |
2020-07-20 09:19:03 -0500 | answered a question | Why does INCREASING the outdoor temperatures on my cooling design days REDUCE my PTAC cooling coil autosized capacities? The moisture content of the air of the updated case could be lower. This then will result in a smaller latent load and t |
2020-07-06 15:50:21 -0500 | answered a question | Using chiller to temper WSHP loop Why not use a cooling tower to do the cooling in this case? EnergyPlus allows plant loops of type "cooling","heating", o |
2020-06-26 09:44:39 -0500 | answered a question | Create a E+ output variable with the sum of all Cooling coil rates Every output variable has a frequency input field. Have you tried using that? |
2020-06-24 14:47:51 -0500 | answered a question | How to create water-cooled VRF in OpenStudio 2.9.1 ? It's possible that this feature is not supported by the OS interface but supported by the SDK through measures. |
2019-08-01 19:51:37 -0500 | received badge | ● Teacher (source) |
2019-08-01 13:32:36 -0500 | answered a question | Default minimum outdoor temperature for DX coils After doing further testing with e+ 8.9, it turns out that the dx heating coil (Coil:Heating:DX:SingleSpeed) can actuall |
2019-07-30 13:25:45 -0500 | commented answer | Default minimum outdoor temperature for DX coils Thanks, this is exactly what I was looking for. |
2019-07-24 16:27:46 -0500 | asked a question | Default minimum outdoor temperature for DX coils Default minimum outdoor temperature for DX coils The current minimum outdoor temperature for compressor operation for En |
2019-01-21 15:02:22 -0500 | received badge | ● Student (source) |
2019-01-20 08:25:46 -0500 | asked a question | E+ VRF model heat recovery mode curves E+ VRF model heat recovery mode curves The E+ model for 'airconditioner:variablerefrigerantflow' does not have defaults |
2018-06-25 14:37:32 -0500 | asked a question | Effect of VAV return fan on average outdoor air intake Effect of VAV return fan on average outdoor air intake I have an OpenStudio project that has 3 VAV systems serving each |