2021-05-08 18:14:16 -0500 edited question PVT and equivalent one diode photovoltaic performance model

PVT and equivalent one diode photovoltaic performance model I am modeling a PVT system on EnergyPlus, when I use Equival

2021-05-08 18:13:24 -0500 edited question PVT and equivalent one diode photovoltaic performance model

PVT and equivalent one diode photovoltaic performance model I am modeling a PVT system on EnergyPlus, when I use Equival

2021-05-08 18:13:02 -0500 commented question PVT and equivalent one diode photovoltaic performance model

You can find below the IDF file: https://drive.google.com/file/d/1--tIaPSghgBzzU39yMaoaHPUDOj_cJL4/view?usp=sharing

2021-05-06 17:09:06 -0500 commented question PVT and equivalent one diode photovoltaic performance model

You can find below the IDF file: https://drive.google.com/file/d/1--tIaPSghgBzzU39yMaoaHPUDOj_cJL4/view?usp=sharing

2021-05-06 06:27:46 -0500 asked a question PVT and equivalent one diode photovoltaic performance model

PVT and equivalent one diode photovoltaic performance model I am modeling a PVT system on EnergyPlus, when I use Equival

2021-03-23 05:56:22 -0500 asked a question Can I integrate different refrigerant in absorption chiller model?

Can I integrate different refrigerant in absorption chiller model? Is it possible to use another refrigerant, besides wa

2021-02-02 03:30:55 -0500 commented answer Can I model a cold storage room using absorption chiller?

That what I concluded also from my research, so I'm trying to get it done with a simple air handling unit. But I'm not s

2021-02-01 06:36:30 -0500 edited question Can I model a cold storage room using absorption chiller?

Can I model a cold storage room using absorption chiller? Is it possible to model a cold storage room using refrigeratio

2021-02-01 03:47:06 -0500 asked a question Can I model a cold storage room using absorption chiller?

Can I model a cold storage room using absorption chiller? Is it possible to model a cold storage room using refrigeratio

2020-12-31 01:44:46 -0500 commented question How can I get a desired temperature at the air outlet of heating coil?

Yes, it is right!

2020-12-29 10:28:57 -0500 commented question How can I get a desired temperature at the air outlet of heating coil?

It is a hot water coil located after the zone return air for the regeneration of desiccant. I want that the heating coil

2020-12-29 07:37:29 -0500 asked a question How can I get a desired temperature at the air outlet of heating coil?

How can I get a desired temperature at the air outlet of heating coil? I tried a controller water coil but it does not w

2020-12-09 01:15:35 -0500 received badge  Supporter (source)
2020-12-08 13:31:10 -0500 marked best answer Severe error calculated density of air is negative

Hello everyone! I am modeling a solar cooling system in EnergyPlus and while running the simulation I've got this severe error:

** Severe  ** PsyRhoAirFnPbTdbW: RhoAir (Density of Air) is calculated <= 0 [-9.04677].
**   ~~~   ** pb =[101100.00], tdb=[-312.09], w=[0.0000000].
**   ~~~   **  Routine=CorrectZoneHumRat, During Warmup, Environment=DSDAYTANGIER COOLING 0.4%, at Simulation time=08/21 00:12 - 00:13
**  Fatal  ** Program terminates due to preceding condition.

I also got a warning that the calculated cooling load is zero, and also the water heater's Recovery Efficiency and Energy Factor could not be calculated during the test for standard ratings.

I tried to hard size the cooling coil but the results are the same.

If anyone could help I'll be grateful. For more details you could find my IDF file in this link: https://drive.google.com/file/d/15HFw...

2020-12-08 13:31:10 -0500 received badge  Scholar (source)
2020-12-08 13:19:50 -0500 commented answer Severe error calculated density of air is negative

Thank you for your contribution, it was very helpful

2020-12-08 04:43:12 -0500 received badge  Student (source)
2020-12-07 03:34:03 -0500 edited question Severe error calculated density of air is negative

Severe error calculated density of air is negative Hello everyone! I am modeling a solar cooling system in EnergyPlus an

2020-12-05 13:59:47 -0500 asked a question Severe error calculated density of air is negative

Severe error calculated density of air is negative Hello everyone! I am modeling a solar cooling system in EnergyPlus an

2020-12-02 13:15:45 -0500 commented answer Debugging EnergyPlus crash

How did you fix the problem of sizing:zone? I have the same issue when I deleted it the software did not crash.

2020-11-13 08:21:09 -0500 commented question Severe error: Component Chiller:Absorption called "ABC" was not found on any plant loops

I'm using EnergyPlus. I think there was a missing node in the object that led to this error, I tried to fix it but now I

2020-11-11 09:29:44 -0500 asked a question Severe error: Component Chiller:Absorption called "ABC" was not found on any plant loops

Severe error: Component Chiller:Absorption called "ABC" was not found on any plant loops Hello, I am modeling an absorpt