2021-07-02 02:58:36 -0500 commented question Calculate Facility Total Building Electric Demand Power

Aaron Boranian I used outputs as: Output:Variable,*,Facility Total Electric Demand Power,Hourly; Output:Variable,*,Fac

2021-06-30 09:34:52 -0500 asked a question Different about Return Air Temperature of Same Zone

Different about Return Air Temperature of Same Zone Hi everyone, I had modeled a simple zone with ElectricEquipment:ITE

2021-06-29 09:33:46 -0500 marked best answer How to reduce the Facility Total HVAC Electric Demand Power

Hi everyone,

I wonder that how I can reduce the Facility Total HVAC Electric Demand Power in my model. After simulation, I see that my DX Coiling Coil had a huge impact on the Facility Total HVAC Electric Demand Power (about 80%). Can some tell me which elements impact on the Facility Total HVAC Electric Demand Power?

Here my HVAC System consists of OutdoorAir:Mixer, Coil:Cooling:DX:SingleSpeed, Fan:VariableVolume and AirTerminal:SingleDuct:ConstantVolume:NoReheat:

image description

Thank all your supports.

2021-06-28 20:53:37 -0500 commented answer How to reduce the Facility Total HVAC Electric Demand Power

Thank you very much. Your advice is very helpful, I'm following it and hoping it will work.

2021-06-27 11:18:49 -0500 asked a question How to reduce the Facility Total HVAC Electric Demand Power

How to reduce the Facility Total HVAC Electric Demand Power Hi everyone, I wonder that how I can reduce the Facility To

2021-06-27 11:18:43 -0500 asked a question How to reduce the Facility Total HVAC Electric Demand Power

How to reduce the Facility Total HVAC Electric Demand Power Hi everyone, I wonder that how I can reduce the Facility To

2021-05-29 04:30:38 -0500 asked a question Calculate Facility Total Building Electric Demand Power

Calculate Facility Total Building Electric Demand Power Hi everyone, I am modeling an Room model that has ElectricEquip

2021-05-09 20:15:47 -0500 commented question Limit value of density ITE load in Zone

@Aaron Boranian Sorry for many posts which are similar in the last month. I have deleted the posts about the same proble

2021-05-08 08:28:50 -0500 asked a question Limit value of density ITE load in Zone

Limit value of density ITE load in Zone I'm modeling the data center by EnergyPlus. When I use 200W/m2 Load of ElectricE

2021-05-08 08:27:43 -0500 asked a question Limit value of density ITE load in Zone

Limit value of density ITE load in Zone I'm modeling the data center by EnergyPlus. When I use 200W/m2 Load of ElectricE

2021-05-06 11:07:28 -0500 commented question High density load in datacenter

@mldichter thanks for your helpful answers. I will try IdealLoadsAirSystem object in my model and I am still waiting for

2021-05-06 10:59:10 -0500 commented question High density load in datacenter

@mldichter I am using the ElectricEquipment:ITE:AirCooled to simulate the server rack load in the data center. My proble

2021-05-06 10:23:51 -0500 commented question High equipment density loads

@HJOJOA Did you find the modification for the high equipment's power load in the data center?

2021-05-06 10:08:28 -0500 commented question High density load in datacenter

@mldichter Did you find the answer to solve these problems above?

2021-05-06 09:59:54 -0500 commented question High density load in datacenter

@HJOJOA Did your find the solution for using high density load in datacenter?

2021-05-05 22:56:38 -0500 commented question The Cooling System can't maintain proper air temperatures in the room

@mdahlhausen I used the default Coil:Cooling:DX:SingleSpeed in 2ZoneDataCenterHVAC_wEconomizer.idf file of EnergyPlus ex

2021-05-05 11:05:11 -0500 commented question The Cooling System can't maintain proper air temperatures in the room

@christon I still have not found the answer.

2021-05-04 02:41:59 -0500 edited question The Cooling System can't maintain proper air temperatures in the room

The Cooling System can't maintain proper air temperatures in the room Hi everyone, I am modeling a data center in Energ

2021-05-04 02:19:33 -0500 edited question The Cooling System can't maintain proper air temperatures in the room

The Cooling System can't maintain proper air temperatures in the room Hi everyone, I am modeling a data center in Energ

2021-05-04 01:08:32 -0500 asked a question The Cooling System can't maintain proper air temperatures in the room

The Cooling System can't maintain proper air temperatures in the room Hi everyone, I am modeling a data center in Energ

2021-05-03 22:51:12 -0500 edited question Severe Error Temperature out of bounds for IT Zone

Severe Error Temperature out of bounds for IT Zone Hi everyone, I am modeling a data center in EnergyPlus based on 2Zon

2021-05-03 11:37:30 -0500 asked a question Severe Error Temperature out of bounds for IT Zone

Severe Error Temperature out of bounds for IT Zone Hi everyone, I am modeling a data center in EnergyPlus based on 2Zon

2021-04-30 00:08:37 -0500 commented question The input Load for ElectricEquipment:ITE:AirCooled did not suitable

@Aaron Boranian My IT Load is 300 kW power and my total floor area is 176 m2. However, it still had severe errors like a

2021-04-28 03:15:55 -0500 commented answer Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Node Relative Humidity

Thank you for the answer.

2021-04-28 03:15:30 -0500 marked best answer Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Node Relative Humidity

Hi everyone,

I used EMS:Sensor to record the Relative Humidity Value of Zone like below:

EnergyManagementSystem:Sensor,
 WestZoneRH,
 West Zone Air Node,
 System Node Relative Humidity;

However, when I print the Output Relative Humidity like below and these values did not match with each other in the same timesteps (example: 20.88% vs 22.52%, 15.68% vs 16.5%, etc. Sometimes it different about 5%). When I record the temperature of the Zone by EMS: Sensor, the values were matched.

Output:Variable,West Zone,Zone Air Relative Humidity,timestep;

Output:Variable,West Zone Air Node,System Node Relative Humidity,timestep;

Can someone find where the problem is and give me some advice?

Thank you for all your supports.

2021-04-27 02:30:22 -0500 edited question Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Node Relative Humidity

Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Nod

2021-04-27 02:30:22 -0500 received badge  Editor (source)
2021-04-27 02:24:59 -0500 asked a question Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Node Relative Humidity

Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Nod

2021-04-23 11:14:08 -0500 commented question The input Load for ElectricEquipment:ITE:AirCooled did not suitable

@Aaron Boranian My IT Load is 300 kWh power and my total floor area is 176 m2. However, it still had severe errors like

2021-04-23 11:13:20 -0500 commented question The input Load for ElectricEquipment:ITE:AirCooled did not suitable

@AaronBoranian My IT Load is 300 kWh power and my total floor area is 176 m2. However, it still had severe errors like a

2021-04-23 11:12:42 -0500 commented question The input Load for ElectricEquipment:ITE:AirCooled did not suitable

@Aaron My IT Load is 300 kWh power and my total floor area is 176 m2. However, it still had severe errors like above. Ca

2021-04-23 11:12:42 -0500 received badge  Commentator
2021-04-22 23:53:26 -0500 asked a question The input Load for ElectricEquipment:ITE:AirCooled did not suitable

The input Load for ElectricEquipment:ITE:AirCooled did not suitable Hi everyone, I am modeling a data center in Energy

2021-04-19 04:39:19 -0500 asked a question Severe Error: Temperature (high) out of bounds (206.46] for zone

Severe Error: Temperature (high) out of bounds (206.46] for zone I simulated the model include OutdoorAirSystem and DX C

2021-04-06 03:11:04 -0500 asked a question Override Outdoor Air Flow Rate Using EMS

Override Outdoor Air Flow Rate Using EMS Hi everyone, I'm using EMS Actuator to override the Out door Air Flow Rate by

2021-03-30 23:03:06 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

@Aaron Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyManagementS

2021-03-30 22:59:57 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

@Aaron Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyManagementS

2021-03-30 22:59:02 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

@Aaron Borannian Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyM

2021-03-30 22:58:36 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

@"Aaron Borannian" Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: Energ

2021-03-30 22:56:14 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

@'AaronBorannian' Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: Energy

2021-03-30 22:55:38 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

@AaronBorannian Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyMa

2021-03-30 22:55:04 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

@Aaron Borannian Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyM

2021-03-30 22:54:23 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

@Aaron Borannian Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyM

2021-03-29 12:49:14 -0500 commented answer Problem with Duplicate Name, Overwriting existing object

Thank you very much. I did not notice that I missed the end of object with a semi-colon. It worked.

2021-03-29 12:48:23 -0500 commented question Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator

I am reading these posts to apply for my model. I will update this comment if it work. Thank you very much for your rep