2021-07-02 02:58:36 -0500 | commented question | Calculate Facility Total Building Electric Demand Power Aaron Boranian I used outputs as: Output:Variable,*,Facility Total Electric Demand Power,Hourly; Output:Variable,*,Fac |
2021-06-30 09:34:52 -0500 | asked a question | Different about Return Air Temperature of Same Zone Different about Return Air Temperature of Same Zone Hi everyone, I had modeled a simple zone with ElectricEquipment:ITE |
2021-06-29 09:33:46 -0500 | marked best answer | How to reduce the Facility Total HVAC Electric Demand Power Hi everyone, I wonder that how I can reduce the Facility Total HVAC Electric Demand Power in my model. After simulation, I see that my DX Coiling Coil had a huge impact on the Facility Total HVAC Electric Demand Power (about 80%). Can some tell me which elements impact on the Facility Total HVAC Electric Demand Power? Here my HVAC System consists of OutdoorAir:Mixer, Coil:Cooling:DX:SingleSpeed, Fan:VariableVolume and AirTerminal:SingleDuct:ConstantVolume:NoReheat: Thank all your supports. |
2021-06-28 20:53:37 -0500 | commented answer | How to reduce the Facility Total HVAC Electric Demand Power Thank you very much. Your advice is very helpful, I'm following it and hoping it will work. |
2021-06-27 11:18:49 -0500 | asked a question | How to reduce the Facility Total HVAC Electric Demand Power How to reduce the Facility Total HVAC Electric Demand Power Hi everyone, I wonder that how I can reduce the Facility To |
2021-06-27 11:18:43 -0500 | asked a question | How to reduce the Facility Total HVAC Electric Demand Power How to reduce the Facility Total HVAC Electric Demand Power Hi everyone, I wonder that how I can reduce the Facility To |
2021-05-29 04:30:38 -0500 | asked a question | Calculate Facility Total Building Electric Demand Power Calculate Facility Total Building Electric Demand Power Hi everyone, I am modeling an Room model that has ElectricEquip |
2021-05-09 20:15:47 -0500 | commented question | Limit value of density ITE load in Zone @Aaron Boranian Sorry for many posts which are similar in the last month. I have deleted the posts about the same proble |
2021-05-08 08:28:50 -0500 | asked a question | Limit value of density ITE load in Zone Limit value of density ITE load in Zone I'm modeling the data center by EnergyPlus. When I use 200W/m2 Load of ElectricE |
2021-05-08 08:27:43 -0500 | asked a question | Limit value of density ITE load in Zone Limit value of density ITE load in Zone I'm modeling the data center by EnergyPlus. When I use 200W/m2 Load of ElectricE |
2021-05-06 11:07:28 -0500 | commented question | High density load in datacenter @mldichter thanks for your helpful answers. I will try IdealLoadsAirSystem object in my model and I am still waiting for |
2021-05-06 10:59:10 -0500 | commented question | High density load in datacenter @mldichter I am using the ElectricEquipment:ITE:AirCooled to simulate the server rack load in the data center. My proble |
2021-05-06 10:23:51 -0500 | commented question | High equipment density loads @HJOJOA Did you find the modification for the high equipment's power load in the data center? |
2021-05-06 10:08:28 -0500 | commented question | High density load in datacenter @mldichter Did you find the answer to solve these problems above? |
2021-05-06 09:59:54 -0500 | commented question | High density load in datacenter @HJOJOA Did your find the solution for using high density load in datacenter? |
2021-05-05 22:56:38 -0500 | commented question | The Cooling System can't maintain proper air temperatures in the room @mdahlhausen I used the default Coil:Cooling:DX:SingleSpeed in 2ZoneDataCenterHVAC_wEconomizer.idf file of EnergyPlus ex |
2021-05-05 11:05:11 -0500 | commented question | The Cooling System can't maintain proper air temperatures in the room @christon I still have not found the answer. |
2021-05-04 02:41:59 -0500 | edited question | The Cooling System can't maintain proper air temperatures in the room The Cooling System can't maintain proper air temperatures in the room Hi everyone, I am modeling a data center in Energ |
2021-05-04 02:19:33 -0500 | edited question | The Cooling System can't maintain proper air temperatures in the room The Cooling System can't maintain proper air temperatures in the room Hi everyone, I am modeling a data center in Energ |
2021-05-04 01:08:32 -0500 | asked a question | The Cooling System can't maintain proper air temperatures in the room The Cooling System can't maintain proper air temperatures in the room Hi everyone, I am modeling a data center in Energ |
2021-05-03 22:51:12 -0500 | edited question | Severe Error Temperature out of bounds for IT Zone Severe Error Temperature out of bounds for IT Zone Hi everyone, I am modeling a data center in EnergyPlus based on 2Zon |
2021-05-03 11:37:30 -0500 | asked a question | Severe Error Temperature out of bounds for IT Zone Severe Error Temperature out of bounds for IT Zone Hi everyone, I am modeling a data center in EnergyPlus based on 2Zon |
2021-04-30 00:08:37 -0500 | commented question | The input Load for ElectricEquipment:ITE:AirCooled did not suitable @Aaron Boranian My IT Load is 300 kW power and my total floor area is 176 m2. However, it still had severe errors like a |
2021-04-28 03:15:55 -0500 | commented answer | Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Node Relative Humidity Thank you for the answer. |
2021-04-28 03:15:30 -0500 | marked best answer | Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Node Relative Humidity Hi everyone, I used EMS:Sensor to record the Relative Humidity Value of Zone like below: However, when I print the Output Relative Humidity like below and these values did not match with each other in the same timesteps (example: 20.88% vs 22.52%, 15.68% vs 16.5%, etc. Sometimes it different about 5%). When I record the temperature of the Zone by EMS: Sensor, the values were matched. Can someone find where the problem is and give me some advice? Thank you for all your supports. |
2021-04-27 02:30:22 -0500 | edited question | Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Node Relative Humidity Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Nod |
2021-04-27 02:30:22 -0500 | received badge | ● Editor (source) |
2021-04-27 02:24:59 -0500 | asked a question | Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Node Relative Humidity Relative Humidity Value Record By EnergyManagemetSystem:Sensor Does Not Match With Relative Humidity Value of System Nod |
2021-04-23 11:14:08 -0500 | commented question | The input Load for ElectricEquipment:ITE:AirCooled did not suitable @Aaron Boranian My IT Load is 300 kWh power and my total floor area is 176 m2. However, it still had severe errors like |
2021-04-23 11:13:20 -0500 | commented question | The input Load for ElectricEquipment:ITE:AirCooled did not suitable @AaronBoranian My IT Load is 300 kWh power and my total floor area is 176 m2. However, it still had severe errors like a |
2021-04-23 11:12:42 -0500 | commented question | The input Load for ElectricEquipment:ITE:AirCooled did not suitable @Aaron My IT Load is 300 kWh power and my total floor area is 176 m2. However, it still had severe errors like above. Ca |
2021-04-23 11:12:42 -0500 | received badge | ● Commentator |
2021-04-22 23:53:26 -0500 | asked a question | The input Load for ElectricEquipment:ITE:AirCooled did not suitable The input Load for ElectricEquipment:ITE:AirCooled did not suitable Hi everyone, I am modeling a data center in Energy |
2021-04-19 04:39:19 -0500 | asked a question | Severe Error: Temperature (high) out of bounds (206.46] for zone Severe Error: Temperature (high) out of bounds (206.46] for zone I simulated the model include OutdoorAirSystem and DX C |
2021-04-06 03:11:04 -0500 | asked a question | Override Outdoor Air Flow Rate Using EMS Override Outdoor Air Flow Rate Using EMS Hi everyone, I'm using EMS Actuator to override the Out door Air Flow Rate by |
2021-03-30 23:03:06 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator @Aaron Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyManagementS |
2021-03-30 22:59:57 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator @Aaron Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyManagementS |
2021-03-30 22:59:02 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator @Aaron Borannian Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyM |
2021-03-30 22:58:36 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator @"Aaron Borannian" Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: Energ |
2021-03-30 22:56:14 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator @'AaronBorannian' Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: Energy |
2021-03-30 22:55:38 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator @AaronBorannian Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyMa |
2021-03-30 22:55:04 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator @Aaron Borannian Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyM |
2021-03-30 22:54:23 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator @Aaron Borannian Is it possible if I use this actuator (from the post you recommended) to control OA flow rate: EnergyM |
2021-03-29 12:49:14 -0500 | commented answer | Problem with Duplicate Name, Overwriting existing object Thank you very much. I did not notice that I missed the end of object with a semi-colon. It worked. |
2021-03-29 12:48:23 -0500 | commented question | Set Fraction Out door air in AirLoopHVAC:OutdoorAirSystem by EMS Sensor and Actuator I am reading these posts to apply for my model. I will update this comment if it work. Thank you very much for your rep |