2024-03-19 06:56:57 -0500 | commented answer | designbuilder simulation error You can use this link or try the search term "internal source" in DesignBuilder's Program Help to find the information y |
2024-02-01 00:52:11 -0500 | answered a question | What are the solutions for modeling natural ventilation in summer? I generally don't comment in conversations like this because it might be perceived as 'commercial' input. But relative t |
2023-07-05 00:06:50 -0500 | commented question | Opening large HTML output file from EnergyPlus Yes, the EP summary report is available in Results Viewer. |
2023-07-05 00:04:18 -0500 | received badge | ● Rapid Responder (source) |
2023-07-05 00:04:18 -0500 | answered a question | Simultaneous modelling of external and internal shading for windows in DesignBuilder Hi, in DesignBuilder you define internal and external shading separately in the Openings tab. Internal shading options c |
2023-03-29 00:17:24 -0500 | received badge | ● Rapid Responder (source) |
2023-03-29 00:17:24 -0500 | answered a question | Help to size HVAC system DesignBuilder I'd suggest first looking at our free tutorials: https://designbuilder.co.uk/training/tutorials There is also more deta |
2022-10-13 05:54:17 -0500 | commented question | Opening large HTML output file from EnergyPlus Just to be clear...you need a license for DesignBuilder itself but you don't need a license for DesignBuilder's (separat |
2022-09-09 04:47:48 -0500 | answered a question | Large model modelling Hi, the only limitations in DesignBuilder on model size are those of EnergyPlus, which as far as I know are not defined |
2022-08-04 10:28:08 -0500 | answered a question | In DesignBuilder split ac system from Simple HVAC template have seasonal heating and cooling COP, what is correct value we can give to heating and cooling COP. If you're a customer you might want to contact our support desk: https://support.designbuilder.co.uk/ Alternatively, y |
2022-05-06 08:12:39 -0500 | commented answer | Designbuilder simple HVAC system COP Different countries and regions have different ways of defining and calculating efficiencies. If the definition being us |
2022-05-06 07:00:10 -0500 | received badge | ● Rapid Responder (source) |
2022-05-06 07:00:10 -0500 | answered a question | Designbuilder simple HVAC system COP The inputs here are those required by EnergyPlus, so the efficiency you specify need to be consistent with EnergyPlus's |
2022-05-04 06:25:45 -0500 | received badge | ● Rapid Responder (source) |
2022-05-04 06:25:45 -0500 | answered a question | How to model a split unit air conditioner in DesignBuilder? There are two "split unit" templates in DesignBuilder Simple HVAC. If you open the list of HVAC templates you will see t |
2022-04-01 00:10:25 -0500 | received badge | ● Rapid Responder (source) |
2022-04-01 00:10:25 -0500 | answered a question | temperature control method (air temperature vs operative temperature) There is a useful discussion on the differences between air and operative temperature control in DesignBuilder's Program |
2022-02-11 09:32:26 -0500 | commented answer | Natural ventilation with wind-powered roof turbine ventilator and earth-tube It's been a few years since I modeled one, but try looking for products like a Monodraught Windcatcher: https://www.mono |
2022-02-11 02:51:10 -0500 | received badge | ● Rapid Responder (source) |
2022-02-11 02:51:10 -0500 | answered a question | Natural ventilation with wind-powered roof turbine ventilator and earth-tube You will find the earth tube option at the bottom of the HVAC tab. I've seen passive roof ventilators modelled to enhanc |
2022-01-06 06:32:57 -0500 | answered a question | How to set a differential thermostat on DesignBuilder DesignBuilder has a team of expert support engineers ready to help customers with technical support. I would suggest you |
2022-01-06 06:32:57 -0500 | received badge | ● Rapid Responder (source) |
2022-01-06 06:31:54 -0500 | answered a question | How can i get Cooling Coil Condensate Volume(m3) using designbuilder?! Following @Aaron Boranian's comment regarding the E+ output variable, you can generate additional/non-standard output va |
2022-01-06 06:26:03 -0500 | answered a question | How to model VFR ODU with AHU in DesignBuilder DesignBuilder has a team of expert support engineers ready to help customers with technical support. I would suggest you |
2021-12-07 00:41:52 -0500 | received badge | ● Rapid Responder (source) |
2021-12-07 00:41:52 -0500 | answered a question | Variable heating/cooling setpoints Hi Elin, I'm assuming you mean the zone heating/cooling setpoints in the Activity tab. On that basis I think there are t |
2021-11-24 06:16:16 -0500 | answered a question | Convergence error in SolveForWindowTemperatures for window - Design Builder DesignBuilder customers have unlimited access to our team of technical support engineers. I suspect from your post that |
2021-11-24 06:16:16 -0500 | received badge | ● Rapid Responder (source) |
2021-10-15 03:33:57 -0500 | received badge | ● Rapid Responder (source) |
2021-10-15 03:33:57 -0500 | answered a question | Simulation result un-affected by choice of "fuel" for heating (DesignBuilder) I'd suggest using DesignBuilder's Program Help and typing in fuel or similar search term to find the information you nee |
2021-10-02 02:42:56 -0500 | answered a question | Where to change "time step" in DesignBuilder DesignBuilder and the interface has changed significantly since the video keb refers to, and now includes many more capa |
2021-10-02 02:42:56 -0500 | received badge | ● Rapid Responder (source) |
2021-09-12 04:25:15 -0500 | received badge | ● Rapid Responder (source) |
2021-09-12 04:25:15 -0500 | answered a question | Unbalanced airflow in a space I don't believe your statement that "my energy modelling software does not allow for modelling unbalanced airflow in a s |
2021-08-17 02:48:46 -0500 | commented answer | Supply air and extract air in DesignBuilder Hi @paulcaicedo, I've asked our tech support team to contact you via the DesignBuilder Support Desk, as UnmetHours or an |
2021-03-18 03:37:31 -0500 | answered a question | Designbuilder cooling load gets zero If DesignBuilder's LEED functionality is included within your license you can automate the baseline building and HVAC sy |
2021-03-18 03:37:31 -0500 | received badge | ● Rapid Responder (source) |
2020-11-14 04:15:06 -0500 | answered a question | how to generate a baseline in designbuilder I'd suggest you read the DesignBuilder LEED and ASHRAE 90.1 User Guide here, which covers both setting up a 90.1 model f |
2020-09-30 03:36:32 -0500 | answered a question | How to compare input of two models in DesignBuilder Comparing IDFs is certainly possible, but perhaps an easier way in DesignBuilder would be to use the Model Data Grid Vie |
2020-08-20 02:32:07 -0500 | answered a question | ACE tool DesignBuilder I used the ACE tool only last week so can confirm it is working as intended in the current release available from the De |
2020-07-20 02:34:51 -0500 | answered a question | baseline and proposed model order in net zero energy buildings Depending on how much knowledge you have of ASHRAE 90.1 it could take a long time to do this manually, but you can autom |
2020-06-24 10:53:28 -0500 | commented answer | Unable to convert an IDF file from design builder. Yes, you can export the IDF from a DesignBuilder model with a Student Personal Licence. To avoid any uncertainty, you ca |
2020-06-12 02:50:46 -0500 | answered a question | Earth tube - Multiple tubes in E+ I may be missing the point here, and if so would gladly be educated, but I would imagine this would be set up in a way t |
2020-06-09 02:20:52 -0500 | answered a question | Earth tube with Heat recovery in E+ or Design builder You mention that you are using DesignBuilder (which includes the earth tube component), so you could also consider using |
2020-05-26 05:16:02 -0500 | answered a question | hourly output loading too large in Design Builder Also take a look at the guidance in the Program Help under the Reference Section (bottom of index) or search on the term |
2020-04-27 09:55:40 -0500 | commented answer | Concrete core activation DesignBuilder DesignBuilder can model embedded pipes in walls, floors and ceilings for radiant heating and/or cooling. You can see the |
2020-04-27 03:51:44 -0500 | answered a question | Concrete core activation DesignBuilder I'd suggest you look at the "internal source" information in DesignBuilder's Program Help here: https://designbuilder.co |
2020-04-24 02:22:03 -0500 | answered a question | Adding multiple chillers in Design-Builder/Energyplus? Tom's point is the most likely reason for only one chiller working. If you haven't already viewed them, I'd suggest you |
2020-04-18 04:36:43 -0500 | answered a question | How to model both natural ventilation and HVAC system in the same building on OpenStudio? In DesignBuilder your primary control for preventing simultaneous heating/cooling/venting is via your indoor environment |
2020-04-17 09:41:22 -0500 | answered a question | Unable to convert an IDF file from design builder. Aaron is correct, some functionality is limited to minimise licence abuse so an evaluation/trial license won't allow an |