2021-05-17 02:17:46 -0500 received badge  Notable Question (source)
2016-09-20 16:44:56 -0500 received badge  Popular Question (source)
2016-02-23 17:54:05 -0500 asked a question How to see output in chart

Hi, I'm using EnergyPlus. I see a study paper that it can show outputs in chart. How to see outputs like temperature, zone mean air temperature, and relative humidity in chart?

2016-02-22 02:33:23 -0500 asked a question unitary vav system cost

Hi everyone, I'm using EnergyPlus. Using the same economics class list, why the VAV system's charge bigger than the unitary system's charge? Its just like not normal. Thanks.

2016-02-21 01:14:26 -0500 asked a question template standard

Hi everyone, I'm using EnergyPlus. I've designed 6 floors building and so many zones and I'm using 3 templates in separately simulation, such as ideal load system template, unitary system template, and VAV system template. I set zone heating setpoint off and zone cooling setpoint for 24C at HVACTemplate:Thermostat (just for cooling and no heating).

My question is : Is there any standard that used for each template (ideal load system template, unitary system template, and VAV system template)? Like ASHRAE standard or anything but different for each template.

Thank you so much for your valuable answers.

2016-02-16 21:55:32 -0500 commented answer cooling design supply air temperature error

Would you like to help me edit my IDF file? I've changed as you suggest but still have this errors :( Thank you so much.

2016-02-15 04:39:10 -0500 commented answer cooling design supply air temperature error

I think the problem is about schedule compact that I have made. What value should I fill below the time in schedule compact? 24 or 1?

2016-02-15 03:49:42 -0500 commented answer cooling design supply air temperature error
  • I did, I have enter to cooling setpoint schedule name.
    • I think they matched
    • I sure

Would you like to help me to see whats wrong in IDF file? IDF file

2016-02-14 19:17:40 -0500 asked a question cooling design supply air temperature error

Hi everyone, I'm using EnergyPlus. I've designed zones and used unitary system template. I set zone heating setpoint off and zone cooling setpoint for 24C at HVACTemplate:Thermostat (just for cooling and no heating). The error :

* Severe * UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature * ~~~ * ...check zone thermostat set point and design supply air temperatures * ~~~ * ...zone name = L1_GUEST_LOUNGE * ~~~ * ...design sensible cooling load = 49979.41 W * ~~~ * ...thermostat set point temp = 0.000 C * ~~~ * ...zone temperature = 12.927 C * ~~~ * ...supply air temperature = 12.800 C * ~~~ * ...temperature difference = -0.12726 C * ~~~ * ...calculated volume flow rate = 394045.60338 m3/s * ~~~ * ...calculated mass flow rate = 473653.03659 kg/s

When I change cooling design supply air temperature from 12,8C to 34,6C, Its still coming error.

* Severe * UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature * ~~~ * ...check zone thermostat set point and design supply air temperatures * ~~~ * ...zone name = L1_GUEST_LOUNGE * ~~~ * ...design sensible cooling load = 97227.21 W * ~~~ * ...thermostat set point temp = 0.000 C * ~~~ * ...zone temperature = 34.603 C * ~~~ * ...supply air temperature = 34.600 C * ~~~ * ...temperature difference = -2.99108E-003 C * ~~~ * ...calculated volume flow rate = 13529.78784 m3/s * ~~~ * ...calculated mass flow rate = 16263.15594 kg/s

What should I do to fix this error? Please help me. I'm in hurry for my project. Thank you.

2016-02-13 18:11:04 -0500 commented answer Errors when using HVACTemplate Unitary System

Thank you so much for answering my question. By the way, I'm using EnergyPlus. Can I do that way in EnergyPlus?

The problem is I've designed this zone just for cooling and no heating so zone heating setpoint is off. I set zone cooling setpoint for 24C.

Thanks

2016-02-13 12:01:38 -0500 asked a question Errors when using HVACTemplate Unitary System

Hi everyone, What make this 2 errors? Thanks

* Warning * GetInternalHeatGains: People="MULTIPURPOSE", Activity Level Schedule Name values * ~~~ * fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. * ~~~ * Odd comfort values may result; Schedule="OCCUPANCY OFFICE". * ~~~ * Entered min/max range=[0.0,1.0] W/person.

* Severe * UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature * ~~~ * ...check zone thermostat set point and design supply air temperatures * ~~~ * ...zone name = L1_ADMINISTRASI_AKADEMIK * ~~~ * ...design sensible cooling load = 50956.13 W * ~~~ * ...thermostat set point temp = 0.000 C * ~~~ * ...zone temperature = 12.875 C * ~~~ * ...supply air temperature = 12.800 C * ~~~ * ...temperature difference = -7.49923E-002 C * ~~~ * ...calculated volume flow rate = 545364.63273 m3/s * ~~~ * ...calculated mass flow rate = 655542.43499 kg/s

2016-02-12 22:48:18 -0500 asked a question Unitary system not meeting cooling load

Hi everyone, I'm using energyplus dan I have a problem when using unitary system template. I see just 0,00 at cooling load, calculated and user design load at output result. I'm not using for heating, just for cooling and cooling setpoint is 24C. Please see my attachment file. What should I change in idf file in order to get cooling load at the output result?

https://www.dropbox.com/s/3j2rz77dcx9...

2016-02-09 20:33:01 -0500 asked a question Error maximum supply air temperature for heating error continues

Hi everyone, What make this error? Thanks

*** * Severe * InitPurchasedAir: For ZoneHVAC:IdealLoadsAirSystem = L3_RUANG_TUTOR_2 IDEAL LOADS AIR SYSTEM serving Zone L3_RUANG_TUTOR_2, maximum supply air temperature for heating error continues *** * ~~~ * This error occurred 2300952 total times; *** * ~~~ * during Warmup 55320 times; *** * ~~~ * during Sizing 0 times. *** * ~~~ * Max=50. C Min=50. C

2016-02-09 06:29:08 -0500 received badge  Student (source)
2016-02-09 01:02:44 -0500 received badge  Editor (source)
2016-02-09 00:42:07 -0500 asked a question How to automatically filled HVACTemplateZone:IdealLoadAirSystem

Hi everyone, I'm sorry if my question is very simple but I don't know. I'm still a newbie.

I have read in this forum the different between conditioned and unconditioned zone is about thermostat. So when in sketchup, I click 'set attributes for selected space' and set yes in set parent thermal zone's - ideal load air system and set one of available choice for conditioned and <clear field=""> for unconditioned in set parent thermal zone's - thermostat.

But when I export to IDF file and then open with IDF Editor, see HVACTemplateZone:IdealLoadAirSystem, I just see unconditioned zone. I need conditioned and unconditioned here. What should I do? Thanks

2016-02-06 21:27:45 -0500 answered a question Set a space as Unconditioned

How about when do you want to set a zone as unconditioned in energyplus (IDF-Editor) or can I set a zone as unconditioned when drawing in SketchUp? What make different between conditioned and unconditioned zone? Thank you

2016-02-06 05:15:21 -0500 received badge  Supporter (source)
2016-02-05 10:04:34 -0500 commented answer Severe error caused by Controller Mechanical Ventilation (OpenStudio 1.5.0)

I'm so sorry. I have looking for the way to post new question but I can't see the way to do it. Please help me, thanks.

2016-02-04 17:17:10 -0500 answered a question Severe error caused by Controller Mechanical Ventilation (OpenStudio 1.5.0)

What if error message * Severe * DesignSpecification:OutdoorAir Name, duplicate name=SZ DSOA L1_GUEST_LOUNGE ??