2024-01-03 21:31:05 -0500 edited question Model crashes with Refrigeration:WalkIn object coupled to Refrigeration:CompressorRack object when heat transfer location is set to "Zone".

Model crashes when using Refrigeration:CompressorRack object with Refrigeration:WalkIn object, when heat transfer locati

2024-01-03 21:14:16 -0500 asked a question Model crashes with Refrigeration:WalkIn object coupled to Refrigeration:CompressorRack object when heat transfer location is set to "Zone".

Model crashes when using Refrigeration:CompressorRack object with Refrigeration:WalkIn object, when heat transfer locati

2023-01-31 19:54:32 -0500 edited question ASHRAE 90.1-2013 Appendix G baseline heating fuel

ASHRAE 90.1-2013 Appendix G baseline heating fuel In ASHRAE 90.1-2013 Table G3.1.1-4, there is a footnote that reads "Wh

2023-01-31 19:54:00 -0500 asked a question ASHRAE 90.1-2013 Appendix G baseline heating fuel

ASHRAE 90.1-2013 Appendix G baseline heating fuel In ASHRAE 90.1-2013 Table G3.1.1-4, there is a footnote that reads "Wh

2022-12-15 11:51:26 -0500 edited question Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly?

Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly? Is there a functio

2022-12-15 11:50:31 -0500 edited question Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly?

Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly? Is there a functio

2022-12-15 11:49:11 -0500 edited question Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly?

Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly? Is there a functio

2022-12-15 11:42:51 -0500 edited question Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly?

Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly? Is there a functio

2022-12-15 11:41:53 -0500 edited question Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly?

Installing EnergyPlus from .exe file vs. just transferring entire program folder? Is there a functional difference betwe

2022-12-15 11:41:45 -0500 edited question Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly?

Installing EnergyPlus from .exe file vs. just transferring entire program folder? Is there a functional difference betwe

2022-12-15 11:38:22 -0500 asked a question Installing EnergyPlus from .exe file vs. just downloading contents of the EnergyPlus folder directly?

Installing EnergyPlus from .exe file vs. just transferring entire program folder? Is there a functional difference betwe

2021-04-02 10:15:44 -0500 edited question Guidance on 90.1-2013 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads)

Guidance on 90.1-2013 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads) Hi all, a

2021-04-02 09:59:07 -0500 edited question Guidance on 90.1-2013 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads)

Guidance on 90.1 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads) Hi all, a quest

2021-04-02 09:58:55 -0500 edited question Guidance on 90.1-2013 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads)

Guidance on 90.1 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads) Hi all, a quest

2021-04-02 09:58:44 -0500 edited question Guidance on 90.1-2013 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads)

Guidance on 90.1 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads) Hi all, a quest

2021-04-02 09:58:11 -0500 edited question Guidance on 90.1-2013 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads)

Guidance on 90.1 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads) Hi all, a quest

2021-01-26 07:26:40 -0500 received badge  Enthusiast
2020-12-29 16:20:44 -0500 asked a question Guidance on 90.1-2013 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads)

Guidance on 90.1 Appendix G system selection, Exception 2 (for spaces with differing peak thermal loads) Hi all, a quest

2020-10-28 14:10:03 -0500 commented answer EnergyPlus 7.0 file

And be sure to compare the results files between the V7 model and original V9 model to verify they are not wildly differ

2020-10-28 14:07:04 -0500 commented answer How do you run your energyplus modeling jobs? (Cloud, local?)

@David Goldwasser in the "Bring your own IDF" example how would you predict simulation speed on the cloud compares to a

2020-07-16 16:15:48 -0500 edited question Why does INCREASING the outdoor temperatures on my cooling design days REDUCE my PTAC cooling coil autosized capacities?

Why does INCREASING the outdoor temperatures on my cooling design days REDUCE my PTAC cooling coil autosized capacities?

2020-07-16 16:14:41 -0500 edited question Why does INCREASING the outdoor temperatures on my cooling design days REDUCE my PTAC cooling coil autosized capacities?

Why does INCREASING the outdoor temperatures on my cooling design days REDUCE my PTAC cooling coil autosized capacities?

2020-07-16 15:55:33 -0500 asked a question Why does INCREASING the outdoor temperatures on my cooling design days REDUCE my PTAC cooling coil autosized capacities?

Why does INCREASING the outdoor temperatures on my cooling design days REDUCE my PTAC cooling coil autosized capacities?

2019-03-04 09:47:03 -0500 edited question Modeling air filter in EnergyPlus to capture particulates during natural ventilation between indoors and outdoors

Modeling air filter to capture particulates during natural ventilation between indoors and outdoors I am attempting to i

2019-03-04 09:39:34 -0500 edited question Modeling air filter in EnergyPlus to capture particulates during natural ventilation between indoors and outdoors

Modeling air filter to capture particulates during natural ventilation airflow between indoors and outdoors I am attempt

2019-03-04 09:38:40 -0500 asked a question Modeling air filter in EnergyPlus to capture particulates during natural ventilation between indoors and outdoors

Modeling air filter to capture particulates during natural ventilation airflow between indoors and outdoors I am attempt

2019-02-28 10:49:10 -0500 edited question Pros & cons of CONTAM/EnergyPlus coupling vs EnergyPlus generic contaminant model

Pros & cons of CONTAM/EnergyPlus coupling vs EnergyPlus generic contaminant model Hi all, I am interested in combin

2019-02-28 10:48:01 -0500 edited question Pros & cons of CONTAM/EnergyPlus coupling vs EnergyPlus generic contaminant model

Pros & cons of CONTAM/EnergyPlus coupling vs EnergyPlus generic contaminant model Hi all, I am interested in combin

2018-07-27 15:42:28 -0500 asked a question Pros & cons of CONTAM/EnergyPlus coupling vs EnergyPlus generic contaminant model

Pros & cons of CONTAM/EnergyPlus coupling vs EnergyPlus generic contaminant model Hi all, I am interested in combin

2018-01-23 16:14:39 -0500 marked best answer Changing composition of atmosphere in EnergyPlus (e.g. increasing CO2 concentration) to simulate effect on envelope convection

As a "fun" project, I'm seeking to simulate the thermal performance of a building envelope in a theoretical atmosphere composed entirely of CO2.

Can EnergyPlus model the resulting effects on interior/exterior convective heat transfer coefficients, say, for blustery conditions in my CO2 atmosphere?

Perhaps a weather file can be manipulated, or convection inputs adjusted, to simulate the effects of this atmosphere?

2017-11-13 13:51:19 -0500 edited question Changing composition of atmosphere in EnergyPlus (e.g. increasing CO2 concentration) to simulate effect on envelope convection

Modeling building envelope convection in an atmosphere composed entirely of CO2? As a "fun" project, I'm seeking to simu

2017-11-13 13:51:18 -0500 edited question Changing composition of atmosphere in EnergyPlus (e.g. increasing CO2 concentration) to simulate effect on envelope convection

Modeling building envelope convection in an atmosphere composed entirely of CO2? As a "fun" project, I'm seeking to simu

2017-11-10 14:27:41 -0500 asked a question Changing composition of atmosphere in EnergyPlus (e.g. increasing CO2 concentration) to simulate effect on envelope convection

Modeling building envelope convection in an atmosphere composed entirely of CO2? I'm seeking to simulate the thermal per

2017-09-19 14:37:58 -0500 commented answer Any example files with micro-CHP system?

Found it, thanks a lot!

2017-09-19 14:37:44 -0500 marked best answer Any example files with micro-CHP system?

Does anyone know of any example models that incorporate CHP systems/cogeneration (e.g. the micro-CHP object in EnergyPlus). Anything from DOE reference buildings to E+ example files, etc.

2017-09-19 14:15:12 -0500 asked a question Any example files with micro-CHP system?

Any example files with micro-CHP system? Does anyone know of any example models that incorporate CHP systems/cogeneratio

2017-04-26 13:14:58 -0500 marked best answer Why incorrect dates on horizontal axis in Results Viewer eso plots?

I'm viewing my ESO files in both xEsoView and DesignBuilder Results Viewer. xEsoView displays graphs with the correct run period (January-December) but for some reason Results Viewer defaults to displaying graphs with incorrect dates on the horizontal axis- the same run period, but it labels the axis August-July. Any suggestions for correcting the dates in Results Viewer? See screenshots below (xExoView on top, Results Viewer on bottom)

image description image description

2017-04-26 13:14:58 -0500 received badge  Scholar (source)
2017-04-25 14:32:29 -0500 edited question Why incorrect dates on horizontal axis in Results Viewer eso plots?

Why incorrect dates on horizontal axis in Results Viewer eso plots? I'm viewing my ESO files in both xEsoView and Design

2017-04-25 14:32:17 -0500 edited question Why incorrect dates on horizontal axis in Results Viewer eso plots?

Why incorrect dates on horizontal axis in Results Viewer eso plots? I'm viewing my ESO files in both xEsoView and Result