First time here? Check out the Help page!
2024-02-27 21:21:51 -0500 | received badge | ● Popular Question (source) |
2022-10-11 14:56:18 -0500 | received badge | ● Popular Question (source) |
2022-04-28 19:39:36 -0500 | received badge | ● Notable Question (source) |
2020-03-10 13:23:04 -0500 | received badge | ● Popular Question (source) |
2019-04-15 11:01:54 -0500 | received badge | ● Popular Question (source) |
2018-08-22 07:49:43 -0500 | marked best answer | Headered Pumps Inputs Hello, I am wondering about some of the inputs for the Headered Variable Speed Pump. I have the information for the pumps and am wondering how I should be inputting them into OpenStudio/EnegryPlus. Say I have the rated flow rate, head, and power consumption of one of the pumps. And the other pump is identical. When I go to input the data into Openstudio/EnergyPlus should I be multiplying the values 2 and inputting that or should I be putting in the value for one of the pumps since they are identical? I guess the thing that is throwing me off is the input number of pumps in bank. I know that is two but are the rest of the inputs related to the sizing of one or both? Thanks in advance. |
2018-05-31 08:35:12 -0500 | marked best answer | Openstudio District Heating and Cooling Hey all first time poster here. Have read many questions/answers that have helped me with the learning of OpenStudio and how various items can be implemented. That being said I have a question regarding the District Heating and Cooling items in the library. I am modelling a building that is part of a campus that has a centralized cooling and heating water system. The hot and cool water are then sent to various buildings, including the one I am modelling, and used for heating and cooling them. My problem is I know the components of the various AHUs and that the cooling and heating coils are using this hot water, I just don't know how I should apply this properly. I have the AHU made but I don't know how to connect the coils up with the district heating/cooling. Do I just make a water loop and add the district heating in the supply portion of the loop and then have a pump and pipe connected to the coil? I think this is the right way to implement this but some guidance would be great. Thanks in advance. Dustin |
2017-11-02 22:15:45 -0500 | received badge | ● Popular Question (source) |
2017-10-15 23:25:38 -0500 | marked best answer | AHU and ERV Contruction I am wondering if I went about modelling this AHU and ERV system correctly. Below is the schematic for the system.
When I modelled it I created my AHU (the right side of the image) using an air loop and the appropriate components. I then simply put an ERV HX on the supply and exhaust nodes of the outdoor air controller. Going back and looking at the schematic I am now thinking I might have over simplified things and that is why some of my results are not as expected. If anyone can give me any insight on how I could model this or if I did initially model it correctly. Should be noted I do my initial work in OpenStudio and do the fine tuning in E+. |
2017-05-19 13:23:41 -0500 | marked best answer | OpenStudio Results Is there any reason why results in the OpenStudio Results tab for monthly electricity consumption is different than what the .idf file outputs? I am asking because I have a model that I need to make some additions/changes to in EnergyPlus and was trying to determine what outputs variables make up the corresponding OpenStudio Electricity Consumption values. I have 5 categories for the electricity consumption breakdown (Heating, Cooling, Interior Lighting, Interior Equipment, and Fans) and I can easily find the outputs variables that make up all but the heating. In my model the only 2 items that should make up the heating are the electric heating coils in the CV Fan Units and the baseboard heaters. When I output the following 2 variables (Zone Unit Heater Heating Energy and Baseboard Electric Energy) and sum the values up and convert to kWh there is a difference (the E+ output is slightly greater in all months, and not by the same amount). If anyone has any insight let me know. |
2017-05-19 13:23:29 -0500 | answered a question | OpenStudio Results Figured it out, was looking at the wrong energy for the unit heaters, had to output the heating coil electric energy. |
2017-05-19 13:06:41 -0500 | asked a question | OpenStudio Results OpenStudio Results Is there any reason why results in the OpenStudio Results tab for monthly electricity consumption is |
2017-05-08 07:25:26 -0500 | answered a question | Sunny and Cloudy day modeling You could probably make a modification to a weather file for an individual day if all you are comparing is the models se |
2017-04-28 08:21:33 -0500 | received badge | ● Popular Question (source) |
2017-02-22 07:11:16 -0500 | answered a question | Do I need to buy SketchUpPro for use with OpenStudio? No you do not need SketchUpPro to use with OpenStudio. The free version of SketchUp works with it just fine. |
2017-01-30 10:17:01 -0500 | marked best answer | Openstudio Calibration not Working I have used the calibration tool in Openstudio but it seems to not be working for me now. The previous building I modelled had just electric energy consumption and I was able to just throw the bill information on the utilities tab with the run year and it worked fine. For the building I am doing now it has three forms of power consumption I am calibrating with. I have the electrical, hot water, and chilled water energy values. Put them in the exact same way as before and with the proper run year. But after the Openstudio simulation is complete the Calibration tab is left empty while the other two tabs have the information in them. Just wondering if any others have had this problem. |
2016-11-23 06:39:32 -0500 | marked best answer | Energy Recovery Ventilation I am wondering how I model an ERV that is attached to one of the AHUs I am trying to model. This is the current loop I have and I need to have the ERV to supply air to the AHU that is mixed with fresh outdoor air. I am still relatively new to OpenStudio and working through issues the best I can. |
2016-08-08 11:08:03 -0500 | asked a question | AHU Humidity Control I am having some trouble knowing what I should be doing to model this AHU in a building that has humidity control. From my understanding, there is a limit on the supply air humidity ratio (SAH) and a setpoint on the return air humidity ratio(RAH) at the AHU level and not at the zone level. I understand that I can put in the SAH in my energy model with one of the setpoint managers, HumidityMaximum I believe. Then comes my confusion, for humidification and de-humidification in energy plus there has to be a ZoneControl:Humidistat which would require a humidifying and de-humidifying schedule applied to each of the zones. What values should I be using for those two schedules is where I am stuck. If anyone has an input that would be great. I have done some digging and came across link text and link text which have helped me understand what is required to control humidity. |
2016-06-23 13:52:53 -0500 | commented answer | Weather file problem in Open Studio Trying looking at the error output text file to help determine what the exact issue is. This has always been useful for me when trying to figure out errors. |
2016-06-08 13:57:39 -0500 | commented answer | OpenStudio Export David thanks for the input. I will definitely want to use it after I have the SketchUp portion of the model done. Would we to be able to view output information such as the HVAC equipment associated with the space for example. I will definitely be looking into this, or maybe some of my coworker who are well versed in programming. Thanks again to you both for the help and pointing me towards some very helpful documents. |
2016-06-08 12:40:32 -0500 | commented answer | OpenStudio Export Thank you very much Eric. This will be an excellent starting point and I, with a good amount of time, could modify this to output more information if required. Thanks for the file location as well I appreciate it. |
2016-06-08 08:11:42 -0500 | commented question | OpenStudio Export Thanks for the quick reply! We are interested in the following information for each space: surfaces and the construction applied to them, the loads in the space, the thermal zone of the space, the equipment in the space. That is what I can think of off the top of my head and looking through OpenStudio. I guess I asked to see if anyone had done something similar and I figured it would be easier to write my own measure outputting the information in the exact format I desire. Thanks for the information will have to do a bit of research on measure writing now. Not at all comfortable with coding. |
2016-06-08 07:39:09 -0500 | asked a question | OpenStudio Export Hey all, I am wondering if there is a way to export the information in the Spaces tab in OpenStudio. My place of employment likes the idea of being able to keep some of the information in these tabs in a spreadsheet that is easy for someone without OpenStudio on their computer to view this information. I am basically wondering if there are any export functions I can use to essentially grab these tables and put them an excel spreadsheet. Not sure if anyone else has ever done this before or if there is an easier way then just manually viewing the tabs in OpenStudio and type all of the entries into a spreadsheet. Thanks in advance. |
2016-04-28 09:57:56 -0500 | marked best answer | 40% Glycol Fluid, OpenStudio Model My questions stems off my recent question regarding district heating/cooling (https://unmethours.com/question/12845...). So I have this central plant that provides hot water and is used for some elements through the building such as radiant panels. The hot water is also sent to a heat exchanger that has a 40% glycol loop for the heating coils of the buildings AHUs. I am wondering how I would go about modelling this and if there is a way in OpenStudio to say that one side of the heat exchanger has water going through it and the other has glycol fluid going through it. I am assuming it will have to be two plant loops that are connected via this heat exchanger. Any help is appreciated. |
2016-04-26 12:24:41 -0500 | asked a question | Radiant Baseboard Sizing I have my simulation up and running and want to eliminate the sizing aspects of the simulation runs. I have ran my simulation once and am looking at my ZoneHVAC:Baseboard:RadiantConvective:Water element. I am trying to fill out the values that were autosized in this variable and am unsure what the output results represent and what the units are. I took a screenshot from the tabular report where I get the sizing of the equipment. The column U-factor times Area [W/C]. I need to know how to turn that value into the Heating Design Capacity value that is currently autosized in my model. If anyone can shed any light on this that would be extremely helpful. |
2016-04-12 18:13:43 -0500 | marked best answer | Setpoint Manager Outdoor Air Reset Hello all, I am wondering if there is setpoint manager similar to the SetpointManager:OutdoorAirReset that can be used to vary a water temperature based on the outdoor air temperature? Thanks |