First time here? Check out the Help page!
2023-03-22 15:15:53 -0500 | commented question | How can I deal with error : "too many fields for object controller: mechanical ventilation" v9.4.0 is what I had been using and the IDD that I had modified, but I've since upgraded the model to v22.2 and updated |
2023-03-16 19:15:59 -0500 | received badge | ● Enthusiast |
2023-03-10 10:57:16 -0500 | commented question | How can I deal with error : "too many fields for object controller: mechanical ventilation" I have tried the solution I believe Ahmed was describing, but it did not work i.e. duplicating the final three items fro |
2017-03-19 18:32:01 -0500 | commented answer | eQuest Geometry to EnergyPlus I've made some progress, but still debugging... In the measure.rb file near the top, change the "release_mode = false" line to equal "true". You'll see an if/then statement below where false is noted as "#For only when using git hub development environment." Since you're actually in OpenStudio, you don't want this to apply. I don't know Ruby and this is my first go at Measures, so any help would be appreciated. Currently running in to this error now, "failed to compute arguments for measure: cannot load such file -- zip" |
2016-10-12 08:31:19 -0500 | received badge | ● Teacher (source) |
2016-10-11 18:54:45 -0500 | answered a question | How do you get CBECC-Com to do the correct Mandatory U-factor checks for Metal Buildings? From CBECC-Com help staff: CBECC-Com applies the Metal Building mandatory u-factor checks to walls that use a construction that includes the material "Metal Siding - 1/16 in." Metal building roofs are those that include a composite material of framing type “metal” with the framing configuration of "RoofMetalScrewDown," "RoofMetalStandingSeam," or "RoofMetalStandingSeamFilledCavity." Any other construction is classified into one of the other categories. |
2016-10-11 18:53:35 -0500 | asked a question | How do you get CBECC-Com to do the correct Mandatory U-factor checks for Metal Buildings? SECTION 120.7 of Title 24-2013 has "MANDATORY INSULATION REQUIREMENTS" which CBECC-Com checks the modeled constructions against. There are different minimum U-factors depending on the type of envelope element (i.e. wall, roof, etc.) and the type of construction (i.e. metal frame, wood frame, etc.) including "Metal Building" constructions. These minimum U-factors are less stringent, so your modeled construction may exceed the typical minimum U-factor and trigger an error in CBECC-Com, but in reality should comply. What materials need to be included to get CBECC-Com to recognize the less stringent Mandatory U-factors for Metal Buildings? |
2015-10-08 15:03:16 -0500 | received badge | ● Student (source) |
2015-10-08 14:16:09 -0500 | asked a question | Is it possible to get a .doe file from eQUEST? I have a spreadsheet set up to read information from .doe files created by EnergyPro and was hoping to reuse it on an eQUEST model. |
2015-08-14 14:01:43 -0500 | received badge | ● Supporter (source) |