First time here? Check out the Help page!
| 2025-06-28 13:51:21 -0500 | commented answer | "Bad allocation" error in EnergyPlus 25.1 with hydronic radiant floor + air-to-water heat pump You're brilliant! You saved me. The problem is solved! Thank you so much! |
| 2025-06-28 13:48:14 -0500 | marked best answer | "Bad allocation" error in EnergyPlus 25.1 with hydronic radiant floor + air-to-water heat pump Hello, I'm modeling a room with a hydronic radiant floor system (ZoneHVAC:LowTemperatureRadiant:VariableFlow) connected to an electric air-to-water heat pump (HeatPump:PlantLoop:EIR:Heating) in EnergyPlus 25.1. My IDF file fails with a "bad allocation" error during sizing calculations, preventing the simulation from starting. IDF link: https://jmp.sh/s/BDXqqMIGvMXxGhNaCDBH Full error log: Program Version,EnergyPlus, Version 25.1.0-68a4a7c774, YMD=2025.06.26 19:28, * Warning * Version: missing in IDF, processing for EnergyPlus version="25.1" * Warning * No reporting elements have been requested. No simulation results produced. * ~~~ * ...Review requirements such as "Output:Table:SummaryReports", "Output:Table:Monthly", "Output:Variable", "Output:Meter" and others. *** Beginning Zone Sizing Calculations * Warning * Calculated design cooling load for zone=NORTH PERIMETER is zero. * ~~~ * Check Sizing:Zone and ZoneControl:Thermostat inputs. * Severe * bad allocation *** Warning: Node connection errors not checked - most system input has not been read (see previous warning). *** Fatal error -- final processing. Program exited before simulations began. See previous error messages. *** ===== Final Error Summary ===== *** The following error categories occurred. Consider correcting or noting. *** No Reporting Elements requested *** ..No Reporting elements have been requested. You will see no output values from your run. *** ..Add Output:Variable, Output:Meter, Output:Table:SummaryReports, Output:Table:Monthly, Output:Table:TimeBins *** ..objects to your input file to receive output values from the simulation. *** EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors. *** EnergyPlus Sizing Error Summary. During Sizing: 1 Warning; 1 Severe Errors. *** EnergyPlus Terminated--Fatal Error Detected. 3 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 0.43sec |
| 2025-06-28 13:48:14 -0500 | received badge | ● Scholar (source) |
| 2025-06-27 11:49:11 -0500 | received badge | ● Student (source) |
| 2025-06-27 09:33:34 -0500 | asked a question | "Bad allocation" error in EnergyPlus 25.1 with hydronic radiant floor + air-to-water heat pump "Bad allocation" error in EnergyPlus 25.1 with hydronic radiant floor + air-to-water heat pump Hello, I'm modeling a ro |