2020-12-05 23:12:19 -0500 | marked best answer | How can I create a virtual load to activate supply side of plant? I need my plant loop pumps to circulate the working fluid during some hours with no actual load. I need this to charge the thermal storage tank during no-load conditions. Thermal storage is placed after the chillers mixer and chillers are controlled by cooling load based operation scheme. Also, my plant loop has no common pipe and has I considered Update: Here is a visual perspective and an additional explanation about the virtual load [Ref]: |
2020-12-05 03:13:35 -0500 | commented question | How can I create a virtual load to activate supply side of plant? @Julien Marrec, Where should I use it? I didn't get your point. Actually, I got the idea of the virtual load from a pap |
2020-12-04 14:28:53 -0500 | edited question | How can I create a virtual load to activate supply side of plant? How can I create a virtual load to activate supply side of plant? I need my plant loop pumps to circulate the working fl |
2020-12-04 14:27:27 -0500 | edited question | How can I create a virtual load to activate supply side of plant? How can I create a virtual load to activate supply side of plant? I need my plant loop pumps to circulate the working fl |
2020-12-04 13:38:29 -0500 | commented question | How can I create a virtual load to activate supply side of plant? @Julien Marrec, Where should I use it? I didn't get your point. Actually I got the idea if virtual load from a paper. I |
2020-12-04 13:38:12 -0500 | commented question | How can I create a virtual load to activate supply side of plant? @Jullien Marrec, Where should I use it? I didn't get your point. Actually I got the idea if virtual load from a paper. I |
2020-12-04 01:23:41 -0500 | received badge | ● Organizer (source) |
2020-12-04 01:23:31 -0500 | edited question | How can I create a virtual load to activate supply side of plant? How can I create a virtual load to activate supply side of plant? I need my plant loop pumps to circulate the working fl |
2020-12-04 01:20:42 -0500 | asked a question | How can I create a virtual load to activate supply side of plant? How can I create a virtual load to activate supply side of plant? I need my plant loop pumps to circulate the working fl |
2020-12-04 01:20:40 -0500 | asked a question | How can I create a virtual load to activate supply side of plant? How can I create a virtual load to activate supply side of plant? I need my plant loop pumps to circulate the working fl |
2020-11-01 05:04:52 -0500 | edited question | best way to evaluate plant sizing results in optimization process best way to evaluate plant sizing results in optimization process I want to optimize chilled water loop sizing and confi |
2020-11-01 05:04:19 -0500 | commented question | best way to evaluate plant sizing results in optimization process @Yi Zhang I provided some details. thanks. |
2020-11-01 05:03:19 -0500 | edited question | best way to evaluate plant sizing results in optimization process best way to evaluate plant sizing results in optimization process I want to optimize chilled water loop sizing and confi |
2020-11-01 05:03:19 -0500 | received badge | ● Editor (source) |
2020-11-01 03:21:52 -0500 | edited question | best way to evaluate plant sizing results in optimization process best way to evaluate plant sizing results in optimization process I want to optimize chilled water loop sizing and confi |
2020-11-01 03:21:35 -0500 | asked a question | best way to evaluate plant sizing results in optimization process best way to evaluate plant sizing results in optimization process I want to optimize chilled water loop sizing and confi |
2020-10-28 08:37:46 -0500 | marked best answer | OpenStudio Plant Sizing issue I have a primary-secondary chiller with common pipe simulation as can be seen below: I want to have primary and secondary loops separated by an ideal heat exchanger. I created an empty water loop and moved my chiller and constant speed pump to its supply side. Then I added the fluid-to-fluid heat exchanger as below: The issue is that the chiller size (autosize and same chiller) is twice as the previous configuration. I believe it should be the same. I appreciate if you got any advice for me. |
2020-10-28 08:30:05 -0500 | asked a question | OpenStudio Plant Sizing issue OpenStudio Plant Sizing issue I have a primary-secondary chiller with common pipe simulation as can be seen below: I |
2020-10-28 08:30:05 -0500 | asked a question | OpenStudio Plant Sizing issue OpenStudio Plant Sizing issue I have a primary-secondary chiller with common pipe simulation as can be seen below: I |
2020-10-28 08:30:04 -0500 | asked a question | OpenStudio Plant Sizing issue OpenStudio Plant Sizing issue I have a primary-secondary chiller with common pipe simulation as can be seen below: I |
2020-10-28 08:30:03 -0500 | asked a question | OpenStudio Plant Sizing issue OpenStudio Plant Sizing issue I have a primary-secondary chiller with common pipe simulation as can be seen below: I |
2020-10-28 08:30:03 -0500 | asked a question | OpenStudio Plant Sizing issue OpenStudio Plant Sizing issue I have a primary-secondary chiller with common pipe simulation as can be seen below: I |
2020-06-14 21:04:10 -0500 | marked best answer | eppy documentation: Isn't it out of date? Hi, I'm starting to learn eppy to hopefully use it for my project. I searched around Unmet Hours and read some of the previous posts. My concern is documentation being out of date. It says that it's "latest" version with no release date. I wonder is it up to date or I should follow GitHub to trace changes? |
2020-06-14 21:04:10 -0500 | received badge | ● Scholar (source) |
2020-06-13 14:43:30 -0500 | asked a question | eppy documentation: Isn't it out of date? eppy documatation: Isn't it out of date? Hi, I'm starting to learn eppy to hopefully use it for my project. I searched a |
2020-06-01 11:03:14 -0500 | commented answer | heating and cooling set-point for air loop supply node @Ag That's a good solution. The problem is that there is no specific schedule for heating or cooling. Somedays both are |
2020-06-01 11:02:27 -0500 | commented answer | heating and cooling set-point for air loop supply node @Ag That's a good solution. The problem is that there is a specific schedule for heating or cooling. Somedays both are r |
2020-06-01 08:34:25 -0500 | received badge | ● Student (source) |
2020-05-31 17:54:26 -0500 | asked a question | heating and cooling set-point for air loop supply node heating and cooling set-point for air loop supply node I am designing a multi-zone AirLoop system that provides cooling |
2020-05-20 12:07:27 -0500 | received badge | ● Supporter (source) |