2020-07-29 04:05:10 -0600 asked a question Locating my IDF file while using "Annual building energy simulation" in Revit.

Locating my IDF file while using "Annual building energy simulation" in Revit. Hi all, I did an architectural design us

2020-07-21 15:17:27 -0600 received badge  Enthusiast
2020-07-03 02:20:31 -0600 commented question EMS actuator keeps the same value for all simulation time?

Thank you, its working

2020-07-02 08:27:35 -0600 edited question EMS actuator keeps the same value for all simulation time?

EMS actuator keeps the same value for all simulation time? Hi all, I have a Loop consisting of HX Liquid to Liquid, Ele

2020-07-02 04:42:14 -0600 edited question EMS actuator keeps the same value for all simulation time?

EMS actuator keeps the same value for all simulation time? Hi all, I have a Loop consisting of HX Liquid to Liquid, Ele

2020-07-02 04:41:53 -0600 asked a question EMS actuator keeps the same value for all simulation time?

EMS actuator keeps the same value for all simulation time? Hi all, I have a Loop consisting of HX Liquid to Liquid, Ele

2020-06-25 07:38:20 -0600 commented answer Cooling Supply with dual compressor chiller and ice thermal storage

Yes, when you have two pumps, one fir supply and one for demand, you should insert a two way common pipe

2020-06-23 03:10:03 -0600 edited answer Cooling Supply with dual compressor chiller and ice thermal storage

I faced the same issue, I did my design using two separate chillers, (A) one for ice storage and (B) one for cooling dur

2020-06-23 03:09:34 -0600 edited answer Cooling Supply with dual compressor chiller and ice thermal storage

I faced the same issue, I did my design using two separate chillers, (A) one for ice storage and (B) one for cooling dur

2020-06-23 03:08:42 -0600 edited answer Cooling Supply with dual compressor chiller and ice thermal storage

I faced the same issue, I did my design using two separate chillers, (A) one for ice storage and (B) one for cooling dur

2020-06-23 03:08:31 -0600 edited answer Cooling Supply with dual compressor chiller and ice thermal storage

I faced the same issue, I did my design using two separate chillers, (A) one for ice storage and (B) one for cooling dur

2020-06-23 03:05:10 -0600 answered a question Cooling Supply with dual compressor chiller and ice thermal storage

I faced the same issue, I did my design using two separate chillers, (A) one for ice storage and (B) one for cooling dur

2020-06-18 10:03:32 -0600 commented question Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling?

Thank you @Aaron https://polymtlca0-my.sharepoint.com/:u:/g/personal/serge_wehbe_polymtl_ca/EardLuGtwhtBg1XDKZSzZ4MBY_1

2020-06-18 10:03:24 -0600 commented question Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling?

Thank you @Aaron https://polymtlca0-my.sharepoint.com/:u:/g/personal/serge_wehbe_polymtl_ca/EardLuGtwhtBg1XDKZSzZ4MBY_1

2020-06-18 09:51:00 -0600 commented question Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling?

Thank you @Aaron https://polymtlca0-my.sharepoint.com/:u:/g/personal/serge_wehbe_polymtl_ca/Ef2fFQdi7P1Hir6JwZmSnJABZHH

2020-06-18 09:50:33 -0600 commented question Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling?

Thank you @Aaron https://polymtlca0-my.sharepoint.com/:u:/g/personal/serge_wehbe_polymtl_ca/Ef2fFQdi7P1Hir6JwZmSnJABZHH

2020-06-18 08:41:08 -0600 commented question Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling?

Thank you @Aaron https://polymtlca0-my.sharepoint.com/:u:/g/personal/serge_wehbe_polymtl_ca/Ef2fFQdi7P1Hir6JwZmSnJABZHH

2020-06-18 08:41:08 -0600 received badge  Commentator
2020-06-18 07:42:01 -0600 edited question Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling?

Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling? Hi all, Im using E+ version 9.3. I used Chiller:Electic:EIR (air

2020-06-18 07:38:45 -0600 asked a question Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling?

Chiller:Electic:EIR VS HeatPump:PlantLoop:EIR:Cooling? Hi all, Im using E+ version 9.3. I used Chiller:Electic:EIR (air

2020-06-17 03:06:50 -0600 marked best answer ChillerHeaterPerformance:Electric:EIR Object In E+?

Hello All,

Could I use ChillerHeaterPerformance:Electric:EIR Object in energyplus as an Air to water Heatpump?

Thank you

2020-06-16 09:06:34 -0600 commented answer Question concerning Table LookUp in EnergyPlus

Done, Thank you

2020-06-16 09:06:08 -0600 marked best answer Question concerning Table LookUp in EnergyPlus

Hi All,

I have create a Lookup Table with an external CSV file and I defined my IndependentVariable and everything was done correctly.

My question is: how to define my independent variable to be the outdoor Air or diffused radiation or (Any EnergyPlus Output value)..

Please here is an example to be more clear:

Outdoor Air (IndependentVariable): -1, 2, 5, 10, 15, 30

Output Value: 100, 200, 300, 400, 500, 600

So if the Ambient Temp is 10 ( For exmp) , I have 400 as output.

How to Link the Outdoor Air (IndependentVariable) to the Outdoor Air Dry Bulb Temperature from my Weather File?

Thank You

2020-06-16 07:24:47 -0600 edited question Question concerning Table LookUp in EnergyPlus

Question concerning Table LookUp in EnergyPlus Hi All, I have create a Lookup Table with an external CSV file and I def

2020-06-16 07:16:21 -0600 asked a question Question concerning Table LookUp in EnergyPlus

Question concerning Table LookUp in EnergyPlus Hi All, I have create a Lookup Table with an external CSV file and I def

2020-06-16 03:24:51 -0600 commented answer ChillerHeaterPerformance:Electric:EIR Object In E+?

Thank you, In the Input output Reference (E+ 9.3): ChillerHeaterPerformance:Electric:EIR has water-cooled as the only v

2020-06-16 03:24:42 -0600 commented answer ChillerHeaterPerformance:Electric:EIR Object In E+?

Thank you, In the Input output Reference (E+ 9.3): ChillerHeaterPerformance:Electric:EIR has water-cooled as the only v

2020-06-16 02:10:58 -0600 commented answer ChillerHeaterPerformance:Electric:EIR Object In E+?

Thank you, In the Input output Reference (E+ 9.3): ChillerHeaterPerformance:Electric:EIR has water-cooled as the only v

2020-06-16 02:06:15 -0600 commented answer ChillerHeaterPerformance:Electric:EIR Object In E+?

Thank you, In the Input output Reference indicated that water-cooled is the only valid condenser type!! But in E+, the

2020-06-16 02:05:47 -0600 commented answer ChillerHeaterPerformance:Electric:EIR Object In E+?

Thank you, In the Input output Reference indicated that water-cooled is the only valid condenser type!! But in E+, the

2020-06-15 13:08:59 -0600 asked a question ChillerHeaterPerformance:Electric:EIR Object In E+?

ChillerHeaterPerformance:Electric:EIR Object In E+? Hello All, Could I use ChillerHeaterPerformance:Electric:EIR Object

2020-06-08 15:39:07 -0600 marked best answer Make My own Output Variable in Energyplus?

Hi all, I would like to create my own output variable from my IDF Output:Variable object.

I have several zone in my building ( for exmp zone 1, 2,3). From my RDD File I have "HVAC,Average,Zone Ideal Loads Zone Sensible Heating Rate [W]".

In the excel File, I obtained:

-Zone 1 Ideal Loads Zone Sensible Heating Rate [W]

-Zone 2 Ideal Loads Zone Sensible Heating Rate [W]

-Zone 3 Ideal Loads Zone Sensible Heating Rate [W]

How to create my own Output variable to be the sum of all Ideal Loads zone sensible heating rate?

Thank you

2020-06-08 02:19:14 -0600 commented question Output data visualization during simulation in E+!

Ah ok, I use them usually. but I thought that I can access the ESO file during simulation

2020-06-07 14:15:28 -0600 commented question Output data visualization during simulation in E+!

Dear Aaron, Im very thankful for your help! Could you please tell me how to accessing the Eso file! I would like to try

2020-06-06 16:03:23 -0600 commented question Output data visualization during simulation in E+!

Thank you Aaron for your help. Didn’t help me! Im searching for a software to visualize the hourly variables graph durin

2020-06-05 15:51:02 -0600 edited question Output data visualization during simulation in E+!

Output data visualization during simulation in E+! Hi all, Is there any software or E+ addin to run in parallel with En

2020-06-05 15:50:57 -0600 edited question Output data visualization during simulation in E+!

Graphical view for output parameters variation during simulation in E+! Hi all, Is there any software or E+ addin to ru

2020-06-05 15:49:21 -0600 edited question Output data visualization during simulation in E+!

Graphical view for output parameters variation during simulation in E+! Hi all, Is there any software or E+ addin to ru

2020-06-05 15:48:57 -0600 edited question Output data visualization during simulation in E+!

Graphical view for output parameters variation during simulation in E+! Hi all, Is there any software or E+ addin to run

2020-06-05 15:48:09 -0600 asked a question Output data visualization during simulation in E+!

Graphical view for output parameters variation during simulation in E+! Hi all, Is there any software or E+ addin to run

2020-05-27 14:29:19 -0600 edited question EMS Error When Using PV Generation as Sensor

EMS Error When Using PV Generation as Sensor Hi all, Im Using EMS in Energy plus for making my Pump ON while my PV syste

2020-05-27 14:28:25 -0600 edited answer Make My own Output Variable in Energyplus?

Thank you a lot. I've tried both methods, and they are working well. Thanks again

2020-05-27 13:22:50 -0600 received badge  Teacher (source)
2020-05-27 09:42:20 -0600 marked best answer EMS Error When Using PV Generation as Sensor

Hi all, Im Using EMS in Energy plus for making my Pump ON while my PV system production is higher than 3000 watts. Here is my Program:

EnergyManagementSystem:Sensor,
  PV_Generation,      !- Name
  Average,                 !- Output:Variable or Output:Meter Index Key Name
  Electric Load Center Produced Electric Power;  !- Output:Variable or Output:Meter Name


EnergyManagementSystem:Actuator,
  CHW_Loop_Sch_Modified,   !- Name
  CHW_Loop_Schd,           !- Actuated Component Unique Name
  Schedule:Compact,        !- Actuated Component Type
  Schedule Value;          !- Actuated Component Control Type

EnergyManagementSystem:ProgramCallingManager,
  CHW_Program,             !- Name
  BeginTimestepBeforePredictor,  !- EnergyPlus Model Calling Point
  System_Storage;          !- Program Name 1

EnergyManagementSystem:Program,
  System_Storage,          !- Name
  IF (PV_Generation > 3000),  !- Program Line 1
    SET CHW_Loop_Sch_Modified = 1,  !- Program Line 2
  ELSE,                    !- A4
    SET CHW_Loop_Sch_Modified = 0,  !- A5
  ENDIF;                   !- A6

I got this Error:

** Invalid Output:Variable or Output:Meter Index Key Name =AVERAGE

** ~~~ ** For Output:Variable or Output:Meter = ELECTRIC LOAD CENTER PRODUCED ELECTRIC POWER

** ~~~ ** Entered in EnergyManagementSystem:Sensor=PV_GENERATION

** ~~~ ** Unique Key Name not found.

Please can someone guide me?

Please note:

  • HVAC,Average,Electric Load Center Produced Electric Power [W] is taken from my RDD File.
  • CHW_Loop_Schd is my pump schedule.

Thank you

2020-05-27 09:42:20 -0600 commented answer EMS Error When Using PV Generation as Sensor

Great, Thank you