2023-03-09 03:35:48 -0500 | commented question | Confusing results when using SimpleGlazingSystem in EnergyPlus @shorowit I am still using E+ 9.3 but I can get reasonable results in the other models. Maybe it might be unique to this |
2023-03-09 03:27:59 -0500 | commented question | Confusing results when using SimpleGlazingSystem in EnergyPlus @Denis Bourgeois thanks for your suggestions. I agree with you that the SimpleGlazingSystem may not be the issue in this |
2023-03-08 02:56:36 -0500 | edited question | Confusing results when using SimpleGlazingSystem in EnergyPlus Unreasonable results when using in EnergyPlus Hi everyone, I'm using WindowMaterial:SimpleGlazingSystem to investigate |
2023-03-08 02:54:37 -0500 | edited question | Confusing results when using SimpleGlazingSystem in EnergyPlus Unreasonable results when using in EnergyPlus Hi everyone, I'm using WindowMaterial:SimpleGlazingSystem to investigate |
2023-03-08 02:54:00 -0500 | edited question | Confusing results when using SimpleGlazingSystem in EnergyPlus Unreasonable results when using in EnergyPlus Hi everyone, I'm using WindowMaterial:SimpleGlazingSystem to investigate |
2023-03-08 02:53:56 -0500 | edited question | Confusing results when using SimpleGlazingSystem in EnergyPlus Unreasonable results when using in EnergyPlus Hi everyone, I'm using WindowMaterial:SimpleGlazingSystem to investigate |
2023-03-08 02:52:38 -0500 | asked a question | Confusing results when using SimpleGlazingSystem in EnergyPlus Unreasonable results when using in EnergyPlus Hi everyone, I'm using WindowMaterial:SimpleGlazingSystem to investigate |
2021-06-03 06:48:08 -0500 | commented answer | How to simulate a variable-speed condenser water pump in EnergyPlus? Thank you so much. I really appreciate your answer and hope this problem can be solved soon. |
2021-06-03 06:33:23 -0500 | marked best answer | How to simulate a variable-speed condenser water pump in EnergyPlus? Hi everyone, I added a variable-speed pump in the condenser loop and changed the "Chiller Flow Mode" to "LeavingSetpointModulated". However, the water flow rate of the variable-speed pump is constant throughout the year, and of course, the power consumption is almost the same as a constant speed pump. I found the same situation happened in this post, and it seems unsolved. Therefore, I was wondering if there is an alternative approach to simulate a variable-speed pump in the condenser loop? Thank you. |
2021-06-03 06:33:23 -0500 | received badge | ● Scholar (source) |
2021-06-03 06:32:21 -0500 | received badge | ● Supporter (source) |
2021-05-27 03:32:34 -0500 | asked a question | How to simulate a variable-speed condenser water pump in EnergyPlus? How to simulate a variable-speed condenser water pump in EnergyPlus? Hi everyone, I added a variable-speed pump in the |