Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

Tanvi's profile - activity

2020-05-26 07:11:59 -0500 edited question DOAS modelling Error

DOAS modelling Error I am modelling a 2 different DOAS systems for multiple Air-side Systems for Compliance analysis. I

2020-05-26 07:11:59 -0500 received badge  Editor (source)
2020-05-24 00:54:48 -0500 asked a question DOAS modelling Error

DOAS modelling Error I am modelling a 2 different DOAS systems for multiple Air-side Systems for Compliance analysis. I

2020-05-21 07:10:45 -0500 asked a question EQuest Envelope Modelling

EQuest Envelope Modelling Hi, I have a basic general Modelling Question. How does EQuest model the envelope. It has mu

2020-05-20 01:23:05 -0500 edited question fluid cooler Curve Issue

fluid cooler Curve Issue Hi, I am modelling the Water-side systems, and this was the error before I edit any default va

2020-05-18 09:55:21 -0500 asked a question fluid cooler Curve Issue

fluid cooler Curve Issue Hi, I started with Systems modelling, and this was the error before I even edit any default va

2020-05-12 23:37:37 -0500 commented answer Equest - Deleting Plenum Thermal Zones

Ok. Yes, it mentions that. Thank you.

2020-05-12 10:30:36 -0500 commented answer Equest - Deleting Plenum Thermal Zones

Yes, I was trying with sun-space and interior window method. Although its getting complicated as well. My goal is to ref

2020-05-12 08:47:04 -0500 marked best answer Equest - Deleting Plenum Thermal Zones

Hi,

I am using equest for the first time, working on a eight storey Library Building with approximately 750 zones (including plenums) and different HVAC systems. The model has multiple plenum spaces and zones allotted to each space. I started deleting few of the thermal plenum zones (for unconditioned utility areas) and the spaces started disappearing, in all the previous versions as well. Eventually, the spaces deleted from all the previous versions as well. Height of the wall is whole floor to floor height, editing that is not fixing the problem.

Please let me know how do I fix this. Thank you.

Tanvi

2020-05-12 04:41:41 -0500 commented answer Equest - Deleting Plenum Thermal Zones

Yes, Sorry issue resolved. The construction was layered, so it had an issue. Thank you. Can you please solve one more

2020-05-12 02:08:10 -0500 commented answer Equest - Deleting Plenum Thermal Zones

Yes, Sorry issue solved. The construction was layered, so it had an issue. Thank you. Can you please solve one more qu

2020-05-11 05:18:26 -0500 asked a question Equest - How to model Glazed interior wall?

Equest - How to model Glazed interior wall? Hi, I tried modelling the interior wall partition(glass) for office. The co

2020-05-11 04:56:16 -0500 commented answer Equest - Deleting Plenum Thermal Zones

Thank you for the solution. I considered the ceiling as air wall, but It had an error "ceiling has no heat capacity". A

2020-05-06 00:11:38 -0500 received badge  Supporter (source)
2020-05-05 17:22:36 -0500 received badge  Student (source)
2020-05-04 17:37:22 -0500 asked a question Equest - Deleting Plenum Thermal Zones

Equest - Deleting Plenum Thermal Zones Hi, I am using equest for the first time, working on a eight storey Library Buil