2023-08-10 13:06:21 -0500 | commented answer | OpenStudio Cooling Load is Zero Hmm, this sounds more like an OpenStudio inputs issue, which I'm not very well versed in. You might want to open up a se |
2023-07-28 11:11:44 -0500 | commented answer | OpenStudio Cooling Load is Zero So what sets the enthalpy_in? That's happening mainly in the zones that are connected to the air loop. If you have not a |
2023-07-28 11:09:20 -0500 | commented answer | OpenStudio Cooling Load is Zero I'm not exactly sure where to find this in OS, but in general each coil is autosized based on the parameters you feed it |
2022-04-24 10:10:23 -0500 | commented question | CAPFTemp curve from operational data Oh, I've definitely seen this myself and hold similar skepticism. This is more as an exercise, and considering a scenari |
2022-04-23 12:17:16 -0500 | commented question | Obtaining Chiller Data from Manufacturers Thanks for the great question, Anna. We are constantly running into this issue as well. Just wanted to update the Taylor |
2022-04-23 11:38:28 -0500 | edited question | CAPFTemp curve from operational data CAPFTemp curve from operational data Hi All! Has anyone successfully generated the CAPFTemp performance curve using op |
2022-04-23 10:56:54 -0500 | commented question | CAPFTemp curve from operational data Hi Jim! Thanks for the info! Eventually I will use the EnergyPlus CurveFitTool for the actual biquad curve generation. |
2022-04-22 16:37:44 -0500 | asked a question | CAPFTemp curve from operational data CAPFTemp curve from operational data Hi All! Has anyone successfully generated the CAPFTemp curve using operational ch |
2021-06-16 10:43:26 -0500 | edited answer | Boiler Hourly Loads Energy Plus Hi Nicole, it seems like there are two main problems: 1) Sizing is not as expected, and 2) Boiler consumption is too hig |
2021-06-16 10:26:41 -0500 | answered a question | Boiler Hourly Loads Energy Plus Hi Nicole, it seems like there are two main problems: 1) Sizing is not as expected, and 2) Boiler consumption is too hig |
2021-06-16 09:09:24 -0500 | received badge | ● Enthusiast |
2021-06-15 11:35:05 -0500 | commented answer | High Pump Energy Consumption Technically this isn't related to your original question, so if you feel like the pump energy consumption question has b |
2021-06-14 11:14:31 -0500 | commented answer | High Pump Energy Consumption The I/O reference is always the go-to for input definitions. Here is the link to the two you asked about. The best plac |
2021-06-14 09:24:19 -0500 | commented answer | High Pump Energy Consumption Hey Ahmad, it's hard to comment on the "correctness" of your input parameters, because it's all relative to the building |
2021-06-14 09:13:07 -0500 | commented question | Boiler Hourly Loads Energy Plus I'm a little confused where you say you think the problem is sizing, but the peak load is very reasonable. Is that 34 kW |
2021-06-10 09:25:43 -0500 | answered a question | Why is my minimum setpoint not met? Sounds like there is not enough load leaving your zone to take the zone temperature below the heating thermostat setpoin |
2021-06-10 09:25:43 -0500 | received badge | ● Rapid Responder (source) |
2021-06-03 17:16:31 -0500 | commented answer | High Pump Energy Consumption Sorry Ahmad, I won't have time to look at your model, but check back in with questions if you're still having issues aft |
2021-06-03 11:21:56 -0500 | commented answer | High Pump Energy Consumption Sorry, that was a lazy reference to the loop_design_temperature_difference in Sizing:Plant. |
2021-06-03 10:30:22 -0500 | answered a question | High Pump Energy Consumption For the issue of high pump power, the easiest thing to do would be to hardsize the power (design_power_consumption) that |
2021-06-02 13:37:39 -0500 | commented question | High Pump Energy Consumption Got it! So is the main problem that the flow is much higher than you expect, or that you expect it to operate with varia |
2021-06-02 09:13:01 -0500 | commented question | High Pump Energy Consumption Hi Ahmad, are you autosizing the design condenser flow for the chiller? If so, you should take a look at your EIO file a |
2021-05-27 14:58:33 -0500 | received badge | ● Commentator |
2021-05-27 14:58:33 -0500 | commented answer | Variable volume fan won't shut off Got it. The flow is based on demand, and therefore zone temperature vs thermostat setpoint. So you may want to take a lo |
2021-05-27 13:03:24 -0500 | received badge | ● Rapid Responder (source) |
2021-05-27 13:03:24 -0500 | answered a question | Variable volume fan won't shut off You might be getting forced by the min flow fraction at the terminal unit(s) (assuming you're using AirTerminal:SingleDu |
2021-05-27 09:37:53 -0500 | answered a question | OpenStudio Cooling Load is Zero If you're autosizing the coil parameters, check your EIO file to check the capacity of your cooling coils. If the capa |
2021-05-27 09:37:53 -0500 | received badge | ● Rapid Responder (source) |
2021-05-27 09:14:24 -0500 | commented question | Variable volume fan won't shut off What object are you using? Is this set up as an airloop, or zone equipment? |
2021-05-24 10:01:32 -0500 | commented answer | Cooling useful energy I don't, but maybe this post will help. |
2021-05-24 09:27:02 -0500 | answered a question | Cooling useful energy Depending on the type of cooling equipment you are using, you might be looking for Output:Meter,CoolingCoils:EnergyTrans |
2021-05-21 09:00:20 -0500 | received badge | ● Rapid Responder (source) |
2021-05-21 09:00:20 -0500 | answered a question | Fan:Systemmodel and ZoneHVAC:FourPipeFanCoil control methods Someone else may know the direct answer to your question, but an alternative option could be to set up an EMS script tha |
2021-05-19 09:18:43 -0500 | commented answer | Secondary Chilled Water Loop Setpoint can't be controlled Nice! Thanks for posting your work! |
2021-05-17 09:40:30 -0500 | received badge | ● Rapid Responder (source) |
2021-05-17 09:40:30 -0500 | answered a question | Secondary Chilled Water Loop Setpoint can't be controlled Well, the good news is that it's trying to make a setpoint, but falling short. You're right to switch to CoolingSetpoint |
2021-05-13 10:39:22 -0500 | received badge | ● Rapid Responder (source) |
2021-05-13 10:39:22 -0500 | answered a question | [eQuest] How does the supply flowrate autosized? Hi Oscar, I'm not familiar with equest, so this may not be very helpful, but for E+ the supply flow autosizing works lik |
2021-05-10 09:21:58 -0500 | edited question | Heat pump cooling coil water flow Heat pump cooling coil water flow Can anyone tell me which parameters are controlling the v_dot_water request for the Co |
2021-05-10 09:17:02 -0500 | commented answer | Economizer high limit doesn't work Jim, another setting to watch out for is in the DesignSpecification:OutdoorAir object. Unless otherwise defined, E+ is u |
2021-05-04 13:31:00 -0500 | asked a question | Heat pump cooling coil water flow Heat pump cooling coil water flow Can anyone tell me which parameters are controlling the v_dot_water request for the Co |
2021-04-21 17:16:10 -0500 | answered a question | Heat Pump Water-to-Air Curves - error on coefficient calculation After doing some testing on this spreadsheet today and then coming across this post, I think the main issue is that it i |
2021-04-09 16:09:17 -0500 | commented answer | can't draw a window as a subsurface or set the WWR on a surface Typically it is true that WWR is more energetically important than location or shape of the window within any given surf |
2021-04-09 09:10:01 -0500 | received badge | ● Rapid Responder (source) |
2021-04-09 09:10:01 -0500 | answered a question | can't draw a window as a subsurface or set the WWR on a surface Hi Brianna! I'm having a little trouble figuring out how the first screenshot fits into the issue, but just in general, |
2020-12-04 11:08:18 -0500 | received badge | ● Editor (source) |
2020-12-04 11:08:18 -0500 | edited answer | create simple tree for energyplus in sketchup You have to initiate a shading surface group first, and then move the object inside of it. You're looking for this butto |
2020-12-04 11:06:13 -0500 | answered a question | create simple tree for energyplus in sketchup You have to initiate a shading surface group first, and then move the object inside of it. You're looking for this butto |
2020-12-04 10:31:39 -0500 | answered a question | Hard Sizing Coil Cooling Water The reason the capacity is not changing is because of the way E+ autosizing routine works. The required capacity of the |
2020-12-02 09:22:38 -0500 | answered a question | Hot gas reheat for an air loop in EnergyPlus Hi Jim, Richard's answer is probably more applicable to your situation, but just in general there is the option to use t |