First time here? Check out the Help page!
1 | initial version |
Hi everyone,
The minimal set of objects to create in order to model electric low temperature radiant heating is indeed :
(1) a Construction object with 2 or more Material objects as layers ; (2) a constructionProperty:InternalHeatSource object located between two layers of the previous Construction object ; (3) a Floor (or Wall, or Roof) object composed of the previous Construction object ; (4) a ZoneHVAC:LowTemperatureRadiant:Electric object linked to the previous Floor object ; (5) a ZoneHVAC:EquipmentList object containing the previous ZoneHVAC:LowTemperatureRadiant:Electric object ; (6) a ZoneHVAC:EquipmentConnections object linked to the previous ZoneHVAC:EquipmentList object and to the thermal zone deserved by the ZoneHVAC:LowTemperatureRadiant:Electric object.
Note that the first field of the ZoneHVAC:EquipmentConnections object isn't its name, but the thermal zone deserved by the equipment list, which can be misleading.
Best regards,
Julien Jakubowski
2 | No.2 Revision |
Hi everyone,
The minimal set of objects to create in order to model electric low temperature radiant heating is indeed :
(1)
Note that the first field of the ZoneHVAC:EquipmentConnections object isn't its name, but the thermal zone deserved by the equipment list, which can be misleading.
Best regards,
Julien Jakubowski