First time here? Check out the Help page!
1 | initial version |
The prior zone volume calculation could result in incorrect volumes for zones with gaps. That's why it now checks for gaps. See the following fixes made in v8.8 #6056 and #6299.
With the posted file it appears that the entered zone volume is being used. Output from v8.9.0
** Warning ** CalculateZoneVolume: 5 zones are not fully enclosed. For more details use: Output:Diagnostics,DisplayExtrawarnings;
And from the eio ouput:
! <Zone Information>,Zone Name,North Axis {deg},Origin X-Coordinate {m},Origin Y-Coordinate {m},Origin Z-Coordinate {m} . . . ,Volume {m3},Zone Inside Convection Algorithm . . .
Zone Information, PLANTABAJA,0.0,0.45,9.66,0.00 . . .,227.08,TARP . . .
And if you add Output:Table:SummaryReports, AllSummary;
, the Input Verification and Results Summary, ZoneSummary shows the entered volumes.
Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3]
PLANTABAJA 79.04 Yes Yes 227.08
SALAESTAR 41.2 Yes Yes 71.15