First time here? Check out the Help page!
1 | initial version |
I had the same error. Oddly enough, I did not have any glycol fluid type in my system.
Although it might seem unrelated... what fixed the problem in my model was correcting the fileds at the WaterHeater:Mixed object. My model had a Solar Tank Storage and a Instantaneous/Tankless system.
Both are modeled as WaterHeater:Mixed objects but for the Solar Tank Storage system the !- Heater Maximum Capacity {W}
filed should be 0 and for the Instantaneous/Tankless system the !- Heater Maximum Capacity {W}
should be 845000
2 | No.2 Revision |
@RChidwick I had the same error. Oddly enough, I did not have any glycol fluid type in my system.
Although it might seem unrelated... what fixed the problem in my model was correcting the fileds at the WaterHeater:Mixed object. My model had a Solar Tank Storage and a Instantaneous/Tankless system.
Both are modeled as WaterHeater:Mixed objects but for the Solar Tank Storage system the !- Heater Maximum Capacity {W}
filed should be 0 and for the Instantaneous/Tankless system the !- Heater Maximum Capacity {W}
should be 845000
3 | No.3 Revision |
@RChidwick I had the same error. Oddly enough, I did not have any glycol fluid type in my system.
Although it might seem unrelated... what fixed the problem in my model was correcting the fileds at the WaterHeater:Mixed object. My model had a Solar Tank Storage and a Instantaneous/Tankless system.
Both are modeled as WaterHeater:Mixed objects but for the Solar Tank Storage system the !- Heater Maximum Capacity {W}
filed should be 0 and for the Instantaneous/Tankless system the !- Heater Maximum Capacity {W}
field should be 845000